Skip to main content
Expedited shipping available at checkout

Eaton / Cutler-Hammer PDG23M0125TFFJ Molded Case Circuit Breaker

  • 125A
  • 3 Pole
  • Panel Mount
Eaton / Cutler-Hammer PDG23M0125TFFJ
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU PDG23M0125TFFJ
Select Item Condition
Earn 1624 SuperPoints
  • 125A
  • 3 Pole
  • Panel Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Eaton / Cutler-Hammer PDG23M0125TFFJ - 125A 3 Pole Molded Case Circuit Breaker

Eaton / Cutler-Hammer PDG23M0125TFFJ - 125A 3 Pole Molded Case Circuit Breaker

New

$1,624.00 In Stock

Quantity

Similar Items

Description

Engineered for commercial use, the Eaton PDG23M0125TFFJ is a 3-pole, 125A molded case circuit breaker. It provides reliable long-time and instantaneous (LI) protection via a fixed thermal-magnetic trip unit. This Frame 2 breaker integrates seamlessly into Eaton Power Defense panelboards and switchboards. It also functions as a direct replacement for the legacy HFD3125.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Part Number PDG23M0125TFFJ
Series PDG2
Amperage 125A
Poles 3
Mounting Style Panel Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC
Fit and installation
Terminal Type Lugs
For Use With Eaton Power Defense Enclosures, Panelboards, Switchboards
Wire Gauge 4 AWG - 4/0 AWG (Al/Cu)
Max Wire 4/0 AWG
Min Wire 4 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Auxiliary Switch, Bell Alarm, Shunt Trip, Undervoltage Release, Padlock Attachment, DIN Rail Adapter, Handle Mechanism
Accessories Line and Load Lugs Included (PDG2X3TA225)
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS
Approval CCC, CE, CSA, IEC, RoHS, UL
Temp Rating -20C to 70C
Construction Features Current Limiting, HACR Rated, RoHS Compliant

Product FAQs

9 answers
What wire sizes and materials are compatible with the lugs on this breaker?

The standard lugs accept both aluminum and copper conductors ranging from 4 AWG to 4/0 AWG. Ensure you apply the correct torque specifications as outlined on the breaker faceplate during installation.

Which enclosures and panels are compatible with the PDG23M0125TFFJ?

This Power Defense Frame 2 breaker is designed for use in Eaton Power Defense enclosures, as well as compatible Eaton panelboards and switchboards that accept Frame 2 panel-mount breakers.

Can the trip settings on this Frame 2 breaker be adjusted in the field?

No. This specific model features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous protection settings are factory-set and cannot be modified.

Is this breaker suitable for high fault current applications at 480V?

Yes, it provides a 65kA interrupting capacity at 480VAC, making it suitable for many commercial and industrial systems requiring robust fault protection. It also carries a 100kA rating at 240VAC.

How is this breaker mounted within a panelboard?

It utilizes a standard panel mount configuration. It bolts directly to the chassis or mounting pan of compatible Eaton switchboards and panelboards.

Can this molded case circuit breaker be used in direct current systems?

Yes, it is rated for use in DC applications up to 250VDC with an interrupting capacity of 22kA. Verify your specific wiring configuration meets Eaton guidelines for DC switching.

Does the Power Defense series replace older Eaton Cutler-Hammer lines?

The Power Defense series is Eaton's modern global breaker platform. While it serves similar applications as the legacy Series C F-Frame breakers, verify physical dimensions and mounting hardware requirements before using it as a direct drop-in replacement.

Does this breaker come with line and load terminals installed?

Yes, it is configured as a feed-thru breaker and includes standard lugs on both the line and load sides for immediate wire termination.

What maintenance is required for the thermal magnetic trip unit?

Thermal magnetic trip units are sealed and require no internal maintenance. Routine visual inspections, verifying lug torque, and exercising the breaker mechanism periodically are recommended to ensure reliable operation.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.