Eaton / Cutler-HammerPDG23M0150TFFJ
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG2 |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Panelboards, Switchboards, Enclosures |
| Wire Gauge | 4 AWG - 4/0 AWG (Al/Cu) |
| Max Wire | 4/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Handle Mechanism |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS |
| Approval | CCC, CE, CSA, IEC, RoHS, UL |
| Temp Rating | -20C to 70C |
| Construction Features | Current Limiting, HACR Rated, RoHS Compliant |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG2 |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Panelboards, Switchboards, Enclosures |
| Wire Gauge | 4 AWG - 4/0 AWG (Al/Cu) |
| Max Wire | 4/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Handle Mechanism |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS |
| Approval | CCC, CE, CSA, IEC, RoHS, UL |
| Temp Rating | -20C to 70C |
| Construction Features | Current Limiting, HACR Rated, RoHS Compliant |
Eaton / Cutler-HammerPDG23M0150TFFJ
Eaton / Cutler-HammerPDG23M0175TFFJ
Eaton / Cutler-HammerPDG23M0175TFFL
Eaton / Cutler-HammerPDG23M0125TFFJ
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDG2 |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 35kA @ 600VAC, 22kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Panelboards, Switchboards, Enclosures |
| Wire Gauge | 4 AWG - 4/0 AWG (Al/Cu) |
| Max Wire | 4/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Handle Mechanism |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS |
| Approval | CCC, CE, CSA, IEC, RoHS, UL |
| Temp Rating | -20C to 70C |
| Construction Features | Current Limiting, HACR Rated, RoHS Compliant |
This Power Defense Frame 2 breaker is designed for direct integration into Eaton Power Defense panelboards, switchboards, and standalone enclosures. It is not intended for use in load centers that require plug-on breakers.
Yes. As a 3-pole complete molded case circuit breaker, it is designed specifically for 3-phase applications. It supports overcurrent and short-circuit protection across 240V, 480V, and 600V AC networks.
Yes, this molded case circuit breaker is rated for continuous DC use up to 250VDC. At this voltage, it provides a 22 kAIC short-circuit interrupting rating.
The terminals on this breaker accept conductors ranging from 4 AWG to 4/0 AWG. The lugs are dual-rated for both aluminum and copper (Al/Cu) wire, allowing flexibility based on your facility's wiring standards.
No, this specific model features fixed thermal and fixed magnetic trip settings. If your application requires field-adjustable long-time or instantaneous pickup curves, you will need a breaker with a Power Xpert electronic trip unit or an adjustable thermal-magnetic unit.
In Eaton's Power Defense nomenclature, the letter M specifies the interrupting rating tier. It confirms the breaker is rated for 65 kAIC at 480VAC and 100 kAIC at 240VAC, which determines its suitability for commercial and industrial systems with high available fault current.
The LI (Long-Time and Instantaneous) thermal-magnetic trip unit provides two layers of safety. The thermal element safely trips the breaker during sustained overloads, while the magnetic element reacts immediately to clear high-level short circuits, minimizing equipment damage.
The PDG23M0150TFFL utilizes a bolt-on connection. Rather than plugging onto the bus, it must be physically bolted to the chassis or bus bars of compatible panelboards and switchboards, ensuring a rigid, low-resistance mechanical connection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.