ABB / General ElectricFBV26TE025RV
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | FBV26TE020RV |
| Series | FBV |
| Amperage | 20A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600Y/347VAC |
| Phase | 1 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 22kA @ 600Y/347VAC |
| Frame Type | FB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series AD Panelboards |
| Wire Gauge | 14-10 AWG (Cu/Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Load Side Lugs Included, Line Connections for AD Panels |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, HACR Rated, Naval Rated, HID Rated, Reverse Feed, Double-Break Rotary Contact Structure, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | FBV26TE020RV |
| Series | FBV |
| Amperage | 20A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600Y/347VAC |
| Phase | 1 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 22kA @ 600Y/347VAC |
| Frame Type | FB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series AD Panelboards |
| Wire Gauge | 14-10 AWG (Cu/Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Load Side Lugs Included, Line Connections for AD Panels |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, HACR Rated, Naval Rated, HID Rated, Reverse Feed, Double-Break Rotary Contact Structure, Non-Interchangeable Trip |
ABB / General ElectricFBV26TE025RV
ABB / General ElectricFBV26TE015RV
ABB / General ElectricFBV26TE030RV
ABB / General ElectricFBV26TE035RV
| Brand | ABB / General Electric |
|---|---|
| Part Number | FBV26TE020RV |
| Series | FBV |
| Amperage | 20A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600Y/347VAC |
| Phase | 1 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 22kA @ 600Y/347VAC |
| Frame Type | FB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series AD Panelboards |
| Wire Gauge | 14-10 AWG (Cu/Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Load Side Lugs Included, Line Connections for AD Panels |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | -25C to 70C |
| Construction Features | Current Limiting, HACR Rated, Naval Rated, HID Rated, Reverse Feed, Double-Break Rotary Contact Structure, Non-Interchangeable Trip |
This breaker is specifically designed for use in General Electric A-Series AD panelboards. The RV suffix in the catalog number indicates it is supplied with load lugs and specialized line connections for direct integration into these panels.
Yes. GE Record Plus FB frame circuit breakers are not marked with line and load designations, meaning they are suitable for reverse feeding applications.
Yes, the Record Plus FB frame supports common field installable internal accessories, including auxiliary switches, shunt trips, undervoltage releases, and bell alarms.
Yes, the GE Record Plus FB series features a current limiting design that utilizes double-break rotary contact structures and ablative materials to reduce arc flash energy and enhance system protection.
This breaker is part of the GE Record Plus FB100 frame family, which covers amperages from 15A up to 100A.
No, this breaker features a fixed thermal magnetic trip unit with non-user interchangeable long-time and instantaneous trip functions.
The included load lugs accept 14 AWG to 10 AWG copper or aluminum (Cu/Al) conductors.
Yes, GE Record Plus FB frame breakers carry HACR (Heating, Air Conditioning, and Refrigeration) and HID (High Intensity Discharge) ratings, making them suitable for HVAC and lighting circuits.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.