ABB / General ElectricSGLC3604L4XX
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | General Electric |
|---|---|
| Part Number | SGHB36BB0400 |
| Series | Spectra |
| Amperage | 400 A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 600V |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC |
| Frame Type | SGHB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | Requires Lug Kit TCLK365: (2) 2/0 AWG-500 kcmil or (1) 8 AWG-600 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 8 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kit |
|---|---|
| Accessories | Includes 400A Rating Plug, Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | -20C to 55C |
| Construction Features | Current Limiting, True RMS Sensing, Reverse Feed, Interchangeable Rating Plug, Visual Trip Indicator, Digital Solid-State Trip Unit |
Quantity
Re-Certified
Quantity
| Brand | General Electric |
|---|---|
| Series | Spectra |
| Amperage | 400 A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 600V |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC |
| Frame Type | SGHB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | Requires Lug Kit TCLK365: (2) 2/0 AWG-500 kcmil or (1) 8 AWG-600 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 8 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kit |
|---|---|
| Accessories | Includes 400A Rating Plug, Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | -20C to 55C |
| Construction Features | Current Limiting, True RMS Sensing, Reverse Feed, Interchangeable Rating Plug, Visual Trip Indicator, Digital Solid-State Trip Unit |
ABB / General ElectricSGLC3604L4XX
ABB / General ElectricSGLC3604L5XX
ABB / General ElectricSGLC3604L7XX
ABB / General ElectricSGLL36AT0400
The General Electric SGHB36BB0400 is a 3 Pole solid state molded case circuit breaker with a current rating of 400 Amps and a voltage rating of 600V. It has an interrupting rating of 35kAIC at 480V. The SGHB36BB0400 has a bolt-on connection type and includes long time, short time, instantaneous and targets trip functions.
| Brand | General Electric |
|---|---|
| Series | Spectra |
| Amperage | 400 A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 600V |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC |
| Frame Type | SGHB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | Requires Lug Kit TCLK365: (2) 2/0 AWG-500 kcmil or (1) 8 AWG-600 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 8 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kit |
|---|---|
| Accessories | Includes 400A Rating Plug, Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | -20C to 55C |
| Construction Features | Current Limiting, True RMS Sensing, Reverse Feed, Interchangeable Rating Plug, Visual Trip Indicator, Digital Solid-State Trip Unit |
This SG-frame breaker is engineered specifically for GE Spectra Series panelboards, switchboards, and motor control centers. It features a bolt-on connection for secure, vibration-resistant mounting in these heavy-duty industrial enclosures.
No, this breaker requires the separate TCLK365 lug kit for wire termination. Once installed, the kit accommodates either two 2/0 AWG to 500 kcmil conductors or a single 8 AWG to 600 kcmil conductor, and is rated for both copper and aluminum wiring.
Yes, GE Spectra RMS electronic trip breakers require a rating plug to establish the continuous ampere rating. You must ensure a compatible SG-frame rating plug, such as one from the SRPG400A series, is installed before commissioning the breaker.
The electronic LSI (Long-Time, Short-Time, Instantaneous) trip unit allows electricians to precisely adjust the breaker time-current curve. This adjustability ensures better selective coordination with downstream devices compared to standard thermal-magnetic breakers.
ABB acquired GE Industrial Solutions in 2018 and transitioned the manufacturing of Spectra Series components. Depending on the production date, your breaker may feature ABB or GE branding, but the physical dimensions, mounting, and performance specifications are completely identical.
Targets are visual indicators on the solid-state trip unit that display the specific cause of a trip event. By showing whether the breaker tripped due to a long-time overload, short-time fault, or instantaneous short circuit, they allow maintenance personnel to diagnose and resolve electrical issues safely and efficiently.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.