ABB / General ElectricSGLC3604L5XX
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGHH36AT0400 |
| Series | SGHH |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 200-400A |
|---|
| Frame Type | SGHH |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 8 AWG-600 kcmil or (2) 2/0 AWG-500 kcmil |
| Max Wire | 600 kcmil |
| Min Wire | 8 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Lug Kits, Rating Plugs |
|---|---|
| Accessories | Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Reverse Feed, True RMS Sensing, 100% Rated, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGHH36AT0400 |
| Series | SGHH |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 200-400A |
|---|
| Frame Type | SGHH |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 8 AWG-600 kcmil or (2) 2/0 AWG-500 kcmil |
| Max Wire | 600 kcmil |
| Min Wire | 8 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Lug Kits, Rating Plugs |
|---|---|
| Accessories | Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Reverse Feed, True RMS Sensing, 100% Rated, Trip-Free Mechanism |
ABB / General ElectricSGLC3604L5XX
ABB / General ElectricSGLC3604L7XX
ABB / General ElectricSGLL36AT0400
ABB / General ElectricSGLC3604L4XX
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGHH36AT0400 |
| Series | SGHH |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 200-400A |
|---|
| Frame Type | SGHH |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 8 AWG-600 kcmil or (2) 2/0 AWG-500 kcmil |
| Max Wire | 600 kcmil |
| Min Wire | 8 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Lug Kits, Rating Plugs |
|---|---|
| Accessories | Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Reverse Feed, True RMS Sensing, 100% Rated, Trip-Free Mechanism |
Yes, this Spectra RMS circuit breaker requires a front-mounted rating plug, such as the SRPG400A400, to establish the continuous ampere rating. The rating plug must be installed for the breaker to function properly.
The standard lugs accept either one wire ranging from 8 AWG to 600 kcmil, or two wires ranging from 2/0 AWG to 500 kcmil. Ensure the cable size matches the ampere rating established by the installed rating plug.
This breaker features a solid-state electronic trip unit with LSI functions. It includes an adjustable instantaneous trip and tracking short-time protection, while the long-time trip point is established by the interchangeable rating plug.
In the GE Spectra RMS series, the SG frame designates a 400A or 600A maximum frame size. The HH in SGHH indicates the specific interrupting capacity tier, which provides 35kAIC at 480VAC and 65kAIC at 240VAC.
This bolt-on SG frame breaker is engineered for use in GE Spectra Series panelboards, switchboards, and motor control centers.
The Spectra RMS series is a legacy General Electric product line. ABB acquired GE Industrial Solutions and now offers the Tmax XT series, such as the XT5N, as a modern replacement which can be installed using a retrofit kit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.