ABB / General ElectricSGLC3604L4XX
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGLC3604L3XX |
| Series | SGLC |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 277VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 65kA @ 600VAC |
| Amperage Range | 200-400A |
|---|
| Frame Type | SGLC |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (2) 2/0 AWG-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 2/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Trip Unit Model | microEntelliGuard |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Lug Kit |
|---|---|
| Accessories | Rating Plug Included, Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, HACR |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Interchangeable Rating Plug |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGLC3604L3XX |
| Series | SGLC |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 277VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 65kA @ 600VAC |
| Amperage Range | 200-400A |
|---|
| Frame Type | SGLC |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (2) 2/0 AWG-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 2/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Trip Unit Model | microEntelliGuard |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Lug Kit |
|---|---|
| Accessories | Rating Plug Included, Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, HACR |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Interchangeable Rating Plug |
ABB / General ElectricSGLC3604L4XX
ABB / General ElectricSGLC3604L5XX
ABB / General ElectricSGLC3604L7XX
ABB / General ElectricSGLA36AT0400
| Brand | ABB / General Electric |
|---|---|
| Part Number | SGLC3604L3XX |
| Series | SGLC |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 277VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 65kA @ 600VAC |
| Amperage Range | 200-400A |
|---|
| Frame Type | SGLC |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Spectra Series Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | (2) 2/0 AWG-500 kcmil (Cu/Al) |
| Max Wire | 500 kcmil |
| Min Wire | 2/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Trip Unit Model | microEntelliGuard |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Lug Kit |
|---|---|
| Accessories | Rating Plug Included, Lugs Not Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489, HACR |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Interchangeable Rating Plug |
This unit-mount SG-frame breaker is engineered for installation within GE Spectra Series panelboards, switchboards, and motor control centers.
The LSI trip unit provides adjustable Long-Time (overload), Short-Time (delayed short-circuit), and Instantaneous (immediate short-circuit) protection. The Short-Time delay function is critical for system coordination, allowing downstream breakers to clear faults before the main breaker trips.
Yes, this breaker requires an interchangeable rating plug to establish the maximum continuous operating current. Operating the breaker without the correct rating plug installed can result in misapplication and a lack of proper overcurrent protection.
Yes. Spectra RMS molded case circuit breakers do not have line or load markings and are fully rated for reverse feed applications. Power cables or busbars can be connected to either the upper or lower terminals.
The standard lugs for this frame accommodate dual parallel runs. Each phase terminal accepts two conductors ranging from 2/0 AWG to 500 kcmil, and is rated for both copper and aluminum wire.
It indicates true RMS (Root Mean Square) sensing within the electronic trip unit. This ensures accurate overcurrent protection by correctly measuring the heating effect of the current, even when harmonic distortion is present from non-linear loads like variable frequency drives.
ABB acquired GE Industrial Solutions, which included the legacy Spectra RMS product line. Depending on the exact manufacturing date, the breaker may feature either an ABB or GE brand label, but the hardware remains identical in fit, form, and function.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.