ABB / General ElectricSKLA36AT1200
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SKLA36AT0800 |
| Series | SKLA |
| Amperage | 800A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 277VAC, 480VAC, 600VAC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 120VAC, 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 42kA @ 600VAC, 100kA @ 120/240VAC |
| Frame Type | SKLA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Spectra Series Switchboards, Power Panels |
| Wire Gauge | 3/0 AWG - 500 kcmil (Al/Cu) [Requires TCAL81 Lug Kit] |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits, Rating Plugs |
|---|---|
| Accessories | Rating Plug (Required, Not Included) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, True RMS Sensing, Interchangeable Rating Plug, Reverse Feed, Solid State |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | SKLA |
| Amperage | 800A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 277VAC, 480VAC, 600VAC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 120VAC, 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 42kA @ 600VAC, 100kA @ 120/240VAC |
| Frame Type | SKLA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Spectra Series Switchboards, Power Panels |
| Wire Gauge | 3/0 AWG - 500 kcmil (Al/Cu) [Requires TCAL81 Lug Kit] |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits, Rating Plugs |
|---|---|
| Accessories | Rating Plug (Required, Not Included) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, True RMS Sensing, Interchangeable Rating Plug, Reverse Feed, Solid State |
ABB / General ElectricSKLA36AT1200
ABB / General ElectricSKLC3608L4XX
ABB / General ElectricSKLL3608L4XX
ABB / General ElectricSKPA36AT0800
Designed for heavy commercial use, this 800A, three-pole Spectra RMS breaker frame provides advanced microprocessor-based protection. The solid-state trip unit ensures highly accurate current monitoring. This SK frame unit installs into GE switchboards using a bolt-on connection. For facilities upgrading legacy gear, ABB suggests the XT7H 800 Ekip Dip LSI as a substitute when paired with a retrofit kit. Adjustable LSI functions allow optimal coordination. A rating plug must be installed.
| Brand | ABB / General Electric |
|---|---|
| Part Number | SKLA36AT0800 |
| Series | SKLA |
| Amperage | 800A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 277VAC, 480VAC, 600VAC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 120VAC, 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 42kA @ 600VAC, 100kA @ 120/240VAC |
| Frame Type | SKLA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Spectra Series Switchboards, Power Panels |
| Wire Gauge | 3/0 AWG - 500 kcmil (Al/Cu) [Requires TCAL81 Lug Kit] |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits, Rating Plugs |
|---|---|
| Accessories | Rating Plug (Required, Not Included) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, True RMS Sensing, Interchangeable Rating Plug, Reverse Feed, Solid State |
Yes. This catalog number is for the breaker frame only and does not include lugs. To terminate your conductors, you must install the TCAL81 lug kit separately, which accepts three 3/0 AWG to 500 kcmil aluminum or copper wires per phase.
No. This breaker requires a field-installable rating plug to establish the continuous ampere rating and operate the electronic trip unit. The breaker will not function properly without the correct front-mounted rating plug installed.
Yes. Spectra RMS molded case circuit breakers do not feature dedicated line or load side markings. Incoming power cables or busbars can be connected to either the upper or lower terminals, making them fully suitable for reverse feed applications.
The solid-state trip system utilizes True RMS sensing and digital sampling. This allows the breaker to accurately calculate the RMS value of both sinusoidal and non-sinusoidal currents, ensuring reliable protection in environments with high harmonic distortion.
The electronic trip unit allows you to adjust the Long-Time, Short-Time, and Instantaneous parameters. This provides precise control over overload and short circuit protection, allowing licensed panel builders to coordinate the breaker with upstream and downstream protective devices in the system.
For facilities completely upgrading legacy gear, ABB recommends the Tmax XT7H 800 Ekip Dip LSI as a direct substitute. Note that installing the newer XT series breakers into older Spectra switchboards requires a specialized retrofit kit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.