ABB / General ElectricSKLB36BB1200
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SKLB36BC1200 |
| Series | SKLB |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 42kA @ 600VAC |
| Amperage Range | 600-1200A |
|---|
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Spectra Series Switchboards, GE A-Series Panelboards, Motor Control Centers |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Adjustable |
| Available Options | Lug Kit, Rating Plugs, Shunt Trip, Auxiliary Switch, Bell Alarm, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | MicroVersaTrip Plus Trip Unit |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | True RMS Sensing, Interchangeable Trip Unit, Visual Trip Indicator, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | SKLB36BC1200-R |
| Series | SKLB |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 42kA @ 600VAC |
| Amperage Range | 600-1200A |
|---|
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Spectra Series Switchboards, GE A-Series Panelboards, Motor Control Centers |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Adjustable |
| Available Options | Lug Kit, Rating Plugs, Shunt Trip, Auxiliary Switch, Bell Alarm, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | MicroVersaTrip Plus Trip Unit |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | True RMS Sensing, Interchangeable Trip Unit, Visual Trip Indicator, Reverse Feed |
ABB / General ElectricSKLB36BB1200
ABB / General ElectricSKLC3612L4XX
ABB / General ElectricSKLC3612L5XX
| Brand | ABB / General Electric |
|---|---|
| Part Number | SKLB36BC1200-R |
| Series | SKLB |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 42kA @ 600VAC |
| Amperage Range | 600-1200A |
|---|
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Spectra Series Switchboards, GE A-Series Panelboards, Motor Control Centers |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Adjustable |
| Available Options | Lug Kit, Rating Plugs, Shunt Trip, Auxiliary Switch, Bell Alarm, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | MicroVersaTrip Plus Trip Unit |
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | CE, CSA, IEC, UL |
| Temp Rating | 40C |
| Construction Features | True RMS Sensing, Interchangeable Trip Unit, Visual Trip Indicator, Reverse Feed |
It indicates the electronic trip unit provides adjustable Long-time overload, Instantaneous short-circuit, and Ground-fault protection. The included ground-fault sensing is essential for commercial equipment protection and is often required by electrical code on main services rated 1000A or higher.
Yes, this Spectra RMS series breaker is fully suitable for reverse fed applications, allowing you to supply incoming line power to either the top or bottom lugs safely.
No, the 1200A SK frame is physically too large for standard residential or light commercial load centers. It is specifically engineered to mount in heavy-duty GE Spectra Series Switchboards, A-Series Panelboards, and compatible Motor Control Centers.
Yes, all GE Spectra SK frame electronic breakers require an interchangeable rating plug to set the active continuous amp rating. To operate this specific breaker at its full 1200A capacity, you will need the matching SRPK1200A1200 rating plug installed.
Yes, the SK frame supports various field-installable internal accessories, including shunt trips, auxiliary switches, and undervoltage releases. These are designed to drop in behind the front accessory cover without breaking the factory mechanism seal.
The Spectra RMS line was originally developed by General Electric. After ABB acquired GE Industrial Solutions, they maintained production and support for this legacy architecture, so the components are now distributed and listed under the combined ABB / General Electric brand.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.