| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB132035WL |
| Series | TEB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 8-3 AWG (Cu/Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Rotary Handle, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism, 50C Ambient Calibration |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB132035WL-R |
| Series | TEB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 8-3 AWG (Cu/Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Rotary Handle, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism, 50C Ambient Calibration |
ABB / General ElectricTEB132040WL
ABB / General ElectricTEB132030WL
ABB / General ElectricTEB132045WL
ABB / General ElectricTEB132025WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB132035WL |
| Series | TEB |
| Amperage | 35A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 8-3 AWG (Cu/Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Rotary Handle, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism, 50C Ambient Calibration |
Following the acquisition of GE Industrial Solutions by ABB, this E150 Line circuit breaker may feature either ABB or GE branding. The physical dimensions, mounting, and electrical specifications remain identical regardless of the label.
The WL suffix specifies that the breaker includes factory-installed line and load side lugs. These lugs are rated for both copper and aluminum conductors.
Yes, GE TEB series molded case circuit breakers are suitable for reverse feed wiring. This provides additional routing flexibility when installing the device in switchboards or motor control centers.
The included line and load lugs accept wire gauges ranging from 8 AWG to 3 AWG. They are dual-rated for use with either copper or aluminum wire.
Yes, the breaker features a trip-free mechanism. This safety feature ensures the breaker will open the circuit under fault conditions even if the handle is physically held or locked in the ON position.
The fixed thermal magnetic trip unit uses a bimetallic strip for long-time overload protection and an electromagnet for instantaneous short circuit protection. Both the thermal and magnetic trip points are fixed and non-adjustable.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.