ABB / General ElectricTED134030WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136030WL |
| Series | TED |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Lugs (TCAL14) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136030WL-R |
| Series | TED |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Lugs (TCAL14) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
ABB / General ElectricTED134030WL
ABB / General ElectricTED136035WL
ABB / General ElectricTED134035WL
ABB / General ElectricTED134025WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136030WL |
| Series | TED |
| Amperage | 30A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Lugs (TCAL14) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
The "WL" suffix indicates that the circuit breaker comes with factory-installed copper and aluminum (Cu/Al) line and load lugs, making it ready for immediate wiring.
The included lugs accept 14 to 3 AWG copper wire or 12 to 1 AWG aluminum wire.
Yes, this breaker is rated for use in DC systems up to 250VDC and 500VDC, providing a 10kA interrupting capacity for both voltage levels.
No, this breaker features a non-interchangeable thermal magnetic trip unit with fixed long-time and instantaneous (LI) trip functions. It cannot be field adjusted.
This unit mount breaker is designed for use in individual enclosures, switchboards, and motor control centers.
Yes, GE TED frame circuit breakers are suitable for reverse feed installations.
Yes, GE TED frame circuit breakers are HACR rated for use with heating, air conditioning, and refrigeration equipment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.