ABB / General ElectricTED136025WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134025WL |
| Series | TED |
| Amperage | 25A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134025WL-R |
| Series | TED |
| Amperage | 25A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
ABB / General ElectricTED136025WL
ABB / General ElectricTED134030WL
ABB / General ElectricTED136030WL
ABB / General ElectricTED134020WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134025WL |
| Series | TED |
| Amperage | 25A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
The "WL" suffix indicates that the breaker comes factory-equipped with both line and load lugs, making it ready for immediate wire termination.
This breaker is part of the General Electric E150 Line, commonly referred to as an E-frame molded case circuit breaker.
Yes, GE TED series breakers are suitable for reverse feed applications, allowing power to be supplied to either the line or load terminals.
No, this is a unit mount, feed-thru circuit breaker. It is designed for standalone applications in individual enclosures, switchboards, and motor control centers rather than traditional plug-on or bolt-on panelboards.
No, this breaker features a fixed thermal-magnetic trip unit. Both the long-time (overload) and instantaneous (short-circuit) trip functions are non-adjustable.
The TED series is a legacy General Electric product line. While it has been largely superseded by newer ABB Tmax XT series breakers for new installations, TED breakers remain widely available for maintaining and upgrading existing infrastructure.
The factory-installed lugs are dual-rated for both copper (Cu) and aluminum (Al) conductors. They accept 14 to 3 AWG copper wire or 12 to 1 AWG aluminum wire.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.