ABB / General ElectricTEY390ST12
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEY390 |
| Series | TEY |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 120VAC, 65kA @ 240VAC, 14kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEY |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 4-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEY390-R |
| Series | TEY |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 120VAC, 65kA @ 240VAC, 14kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEY |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 4-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
ABB / General ElectricTEY390ST12
ABB / General ElectricTEY3100ST12
ABB / General ElectricTEY380ST12
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEY390 |
| Series | TEY |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 120VAC, 65kA @ 240VAC, 14kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEY |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 4-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
This bolt-on breaker is designed for GE and ABB A-Series panelboards. It secures directly to the internal panel bus structure and is not compatible with standard Q-Line residential load centers.
No. Because it carries a slash voltage rating of 480Y/277VAC, it is strictly approved for grounded WYE systems where the line-to-ground voltage does not exceed 277V. It cannot be used on ungrounded or corner-grounded Delta configurations.
Yes. Following the acquisition of GE Industrial Solutions by ABB, this breaker line is manufactured under the ABB brand. It retains the exact same physical dimensions, mounting hardware, and electrical ratings as legacy GE models.
Only if a fault current analysis confirms that the available short-circuit current is 14 kA or less at 480Y/277V. The TEY390 is the standard-interrupting version. Higher-tier models like the TEYD (25 kA) or TEYL (65 kA) are required for systems with higher fault current potentials.
Yes, this breaker is HACR rated. This certification verifies it is approved for the branch-circuit protection of heating, air conditioning, and refrigeration systems.
Yes, TEY series molded case circuit breakers do not have restrictive line or load direction markings and can be safely reverse fed in back-fed main breaker applications.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.