| Brand | ABB / General Electric |
|---|---|
| Series | TEYD |
| Amperage | 125A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEYD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Lighting Panelboards |
| Wire Gauge | 4 AWG - 2/0 AWG (Cu/Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment, Mounting Base |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
It mounts directly into GE A-Series lighting panelboards [1.2.7]. This includes AQ, AE, AD, and AS panelboard types that are configured for TEY-frame bolt-on branch breakers.
The primary difference is the short-circuit interrupting rating. The TEYD offers 25kAIC at 480Y/277VAC. For systems with higher available fault currents, the TEYH and TEYL models provide higher interrupting capacities of 35kAIC and 65kAIC, respectively.
Yes, standard TEYD branch breakers come with factory-installed load lugs. As a bolt-on breaker, the line side features a mechanical connection that bolts directly to the panelboard bus.
Yes. TEYD thermal-magnetic circuit breakers do not have Line or Load markings and are suitable for reverse-feed applications. Always ensure installation complies with National Electrical Code (NEC) requirements for back-fed breakers, such as using an approved retaining kit.
No, this breaker features a non-interchangeable, fixed thermal-magnetic trip unit. Both the long-time (thermal) and instantaneous (magnetic) trip points are factory set.
Yes, it is rated for up to 250VDC with a 10kA interrupting capacity, making it an option for compatible DC control panels or power distribution systems.
The GE TEYXPLD1 padlock device fits TEYD, TEYH, and TEYL frame circuit breakers for lockout/tagout safety procedures.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.