ABB / General ElectricTEYL2045B
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEYL2050B |
| Series | TEYL |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125VDC, 250VDC, 120/240VAC |
| Phase | 1 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480Y/277VAC, 42kA @ 125VDC, 20kA @ 250VDC, 100kA @ 120/240VAC |
| Frame Type | TEYL |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 10-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Quick-Make/Quick-Break, Common Trip, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEYL2050B-R |
| Series | TEYL |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125VDC, 250VDC, 120/240VAC |
| Phase | 1 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480Y/277VAC, 42kA @ 125VDC, 20kA @ 250VDC, 100kA @ 120/240VAC |
| Frame Type | TEYL |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 10-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Quick-Make/Quick-Break, Common Trip, Non-Interchangeable Trip |
ABB / General ElectricTEYL2045B
ABB / General ElectricTEYL2060B
ABB / General ElectricTEYL2040B
ABB / General ElectricTEYL2035B
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEYL2050B |
| Series | TEYL |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125VDC, 250VDC, 120/240VAC |
| Phase | 1 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480Y/277VAC, 42kA @ 125VDC, 20kA @ 250VDC, 100kA @ 120/240VAC |
| Frame Type | TEYL |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 10-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Quick-Make/Quick-Break, Common Trip, Non-Interchangeable Trip |
This breaker is designed for bolt-on installation in ABB and GE A-Series lighting panelboards. It will not fit standard residential plug-on load centers.
The difference is the short-circuit interrupting rating. The standard TEY frame is rated for 14kA at 480/277V, while the TEYL frame offers a higher interrupting capacity of 65kA at 480/277V. Both are 50A, 2-pole breakers that fit A-Series panelboards.
Yes, this thermal-magnetic breaker is UL listed for DC applications. It provides an interrupting capacity of 42kA at 125VDC and 20kA at 250VDC.
The standard lugs on this breaker accept 10 AWG to 4 AWG conductors. They are suitable for use with both copper and aluminum wiring.
No, this breaker features a fixed thermal-magnetic trip unit. It provides standard Long-Time and Instantaneous (LI) protection functions that cannot be field-adjusted.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.