ABB / General ElectricTFJ236150WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236125WL |
| Series | TFJ |
| Amperage | 125A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator |
|---|---|
| Accessories | Includes Line and Load Lugs (TCAL25) |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236125WL-R |
| Series | TFJ |
| Amperage | 125A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator |
|---|---|
| Accessories | Includes Line and Load Lugs (TCAL25) |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTFJ236150WL
ABB / General ElectricTFJ236100WL
ABB / General ElectricTFJ236090WL
ABB / General ElectricTFJ236175WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236125WL-R |
| Series | TFJ |
| Amperage | 125A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator |
|---|---|
| Accessories | Includes Line and Load Lugs (TCAL25) |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
This F-Frame unit mount breaker is designed for installation in legacy GE A-Series panelboards, Spectra Series panelboards, commercial switchboards, motor control centers, and individual enclosures.
In GE circuit breaker part numbers, the WL suffix indicates that the breaker is supplied from the factory with both line-side and load-side lugs installed.
The TFJ frame is a legacy GE product. For facilities looking to modernize, this breaker can be replaced by the ABB Tmax XT4 series when paired with the appropriate retrofit kit.
The factory-installed lugs accept copper or aluminum conductors ranging from 4 AWG to 300 kcmil. Always verify local electrical codes and apply the correct torque values when terminating conductors.
This breaker features a thermal magnetic trip unit. It provides fixed thermal protection for long-time overloads and an adjustable magnetic dial to fine-tune the instantaneous short-circuit response based on your specific load requirements.
Yes, this breaker is rated for both AC and DC applications. It can be safely deployed in DC systems, providing a 10kA interrupting capacity at 250VDC and 500VDC.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.