ABB / General ElectricTFK236175WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFK236150WL |
| Series | TFK |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TFK |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip Unit |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFK236150WL-R |
| Series | TFK |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TFK |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip Unit |
ABB / General ElectricTFK236175WL
ABB / General ElectricTFK236125WL
ABB / General ElectricTFK236200WL
ABB / General ElectricTFK236100WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFK236150WL-R |
| Series | TFK |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TFK |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Line and Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Interchangeable Trip Unit |
The WL suffix indicates that the circuit breaker comes equipped with factory-installed line and load lugs, making it ready for immediate feed-thru wiring.
This F-frame breaker is designed for installation in GE A-Series panelboards, Spectra Series switchboards, motor control centers, and standalone enclosures.
The included lugs accept wire gauges ranging from 4 AWG to 300 kcmil.
This breaker features a thermal magnetic trip unit with a fixed thermal setting for long-time overload protection and an adjustable magnetic setting for instantaneous short-circuit protection.
GE Industrial Solutions was acquired by ABB. Depending on the manufacturing date, this breaker may arrive with either ABB or General Electric branding, but the physical dimensions and technical specifications remain identical.
Yes, the TFK236150WL is rated for DC applications and provides an interrupting capacity of 10kA at 250VDC.
Yes, the TFK frame utilizes an interchangeable trip unit. This allows the trip mechanism to be replaced or upgraded without removing the entire breaker frame from the panelboard.
No, TFK frame breakers feature interchangeable trip units and are not suitable for reverse feed applications. If reverse feeding is required, a non-interchangeable frame like the TFJ series is typically used.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.