ABB / General ElectricTHED136045WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136040WL |
| Series | THED |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, HID Rated, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip, High Interrupting Capacity |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136040WL-R |
| Series | THED |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, HID Rated, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip, High Interrupting Capacity |
ABB / General ElectricTHED136045WL
ABB / General ElectricTHED136035WL
ABB / General ElectricTHED136050WL
ABB / General ElectricTHED136030WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136040WL |
| Series | THED |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, HID Rated, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip, High Interrupting Capacity |
The WL suffix indicates that the circuit breaker is supplied with factory-installed lugs on both the line and load sides for wire termination.
Both models belong to the GE E-150 frame family and share the same physical dimensions. However, THED breakers offer a higher interrupting capacity than standard TED breakers.
This unit-mount breaker is designed for installation in GE enclosures, switchboards, and motor control centers that are configured to accept E-frame circuit breakers.
No, this model features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous trip functions are factory set and cannot be adjusted in the field.
The THED136040WL is a unit-mount circuit breaker. It is secured using mounting hardware and wired via lugs, rather than plugging directly onto a panelboard bus like a standard branch breaker.
Yes, this breaker is rated for DC applications up to 500VDC. It provides a 10kA interrupting capacity for both 250VDC and 500VDC systems.
Yes, the lugs are rated for both copper and aluminum conductors. They accept 14 to 3 AWG copper wire or 12 to 1 AWG aluminum wire.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.