ABB / General ElectricTHED136070WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136060WL |
| Series | THED |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | THED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14 AWG - 3 AWG (Cu), 12 AWG - 1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip, High Interrupting Capacity |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136060WL-R |
| Series | THED |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | THED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14 AWG - 3 AWG (Cu), 12 AWG - 1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip, High Interrupting Capacity |
ABB / General ElectricTHED136070WL
ABB / General ElectricTHED136050WL
ABB / General ElectricTHED136045WL
ABB / General ElectricTHED136080WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136060WL |
| Series | THED |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | THED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14 AWG - 3 AWG (Cu), 12 AWG - 1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Common Trip, High Interrupting Capacity |
This circuit breaker is part of the General Electric E-150 product line. The E-150 frame size includes thermal-magnetic breakers and molded case switches rated for up to 150 amps.
The WL suffix means this breaker is shipped from the factory with copper and aluminum (Cu/Al) line and load lugs already installed.
The included lugs are rated to accept 14 AWG to 3 AWG copper wire, or 12 AWG to 1 AWG aluminum wire.
It is a unit-mount device designed specifically for installation in compatible General Electric individual enclosures, industrial switchboards, and motor control centers.
The LI code indicates that the breaker provides Long-Time and Instantaneous protection. It uses fixed thermal and fixed magnetic elements to protect against overloads and short circuits.
No, this unit features a non-interchangeable trip unit with fixed thermal and fixed magnetic settings, meaning the trip points cannot be manually adjusted.
Yes. In addition to standard AC voltages, it is rated for direct current applications with an interrupting capacity of 10kA at both 250VDC and 500VDC.
The H signifies a higher interrupting capacity compared to standard breakers in the E-150 line, such as the TED frame. This model delivers up to 65kA interrupting capacity at 240VAC and 25kA at 480VAC.
ABB acquired GE Industrial Solutions. Depending on the exact manufacturing date, the breaker may carry either the ABB or GE brand label, but the fit, form, and function are completely identical.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.