Supplying 100 amps of protection, the MP3100 is a three-pole miniature breaker for commercial use. It utilizes fixed thermal and magnetic trip elements to clear overloads. The plug-on design installs seamlessly into Murray and Siemens load centers. It is ideal for maintaining existing infrastructure and is cross-referenced to the Q3100 replacement. Operating at 240VAC, this breaker provides a 10 kAIC rating. It is HACR rated and features a common trip mechanism.
Are Murray and Siemens MP3100 breakers the exact same component?
Yes. Siemens manufactured the Murray product line before officially phasing out the brand. A Siemens MP3100 and a Murray MP3100 are identical Type MP-T breakers and function exactly the same in compatible load centers.
What is the current Siemens replacement for the MP3100?
The Siemens Q3100 is the direct, UL-approved replacement. Siemens issued an official substitution letter authorizing the use of Type QP breakers (like the Q3100) in place of legacy Type MP-T breakers (like the MP3100) for Murray and Siemens panels.
Is this breaker HACR rated for HVAC equipment?
Yes, the MP3100 carries an HACR rating. It is fully approved for use with heating, air conditioning, and refrigeration motor loads that require this specific safety designation.
Does this breaker provide GFCI or AFCI protection?
No. The MP3100 is a standard thermal-magnetic circuit breaker providing only overload and short-circuit protection. It does not include ground fault (GFCI) or arc fault (AFCI) circuitry.
What does the LI trip function indicate on this breaker?
The LI designation means the breaker provides Long-Time (thermal) and Instantaneous (magnetic) trip functions. The thermal element protects against sustained overloads, while the magnetic element trips immediately during a short circuit.
Can I use the MP3100 in a system with a 22kAIC fault current requirement?
No. The MP3100 has a maximum interrupting rating of 10kA at 240V AC. If your panel or local code requires a 22kAIC or higher rating, you must source a fully rated or series-rated breaker that meets that specification.
Are the load lugs on the MP3100 rated for aluminum wiring?
Yes, the factory lugs are dual-rated for both copper (Cu) and aluminum (Al) conductors. Ensure you use the correct wire gauge and apply an approved oxide inhibitor when terminating aluminum wire.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 4 reviews.
Thank you so much for sending me a 100 amp breaker that was in the condition that you said it would be in.With out your breaker I would still be in the dark Thank you David