Square D HJA36100SA Molded Case Circuit Breaker

  • 100A
  • 3 Pole
  • I-Line
Square D HJA36100SA
Molded Case Circuit Breaker
Brand Square D
SKU HJA36100SA
Select Item Condition
Earn 1798 SuperPoints
  • 100A
  • 3 Pole
  • I-Line

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Square D HJA36100SA 3 Pole Circuit Breaker

Square D HJA36100SA - 100A 3 Pole Molded Case Circuit Breaker

New

$1,798.00 In Stock

Quantity

Similar Items

Description

Providing advanced control for industrial systems, the Square D HJA36100SA is a 3-pole, 100A molded case circuit breaker. It includes a factory-installed 120VAC shunt trip, enabling remote disconnection for emergency shutdowns. This PowerPact H-Frame breaker utilizes an I-Line mounting configuration, fitting perfectly into Square D I-Line panelboards. It serves as a cross-reference for the legacy FA361001021. The unit delivers a 65 kAIC rating at 480VAC and features a thermal-magnetic trip.

Specifications

Key specifications
Brand Square D
Part Number HJA36100SA
Series HJA
Amperage 100A
Poles 3
Mounting Style I-Line
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC, 20kA @ 250VDC
Fit and installation
Frame Type HJA
Terminal Type Lugs
For Use With Square D I-Line Panelboards, Square D I-Line Switchboards
Wire Gauge 14-3/0 AWG (Al/Cu)
Max Wire 3/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle
Accessories Shunt Trip 120VAC (Factory Installed)
Standards CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval CE, CSA, IEC, NOM, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Current Limiting, Visual Trip Indicator, Reverse Feed, 80% Rated

Product FAQs

8 answers
What does the "SA" suffix indicate on the HJA36100SA?

The "SA" suffix means this breaker comes with a factory-installed 120VAC shunt trip accessory. This allows the breaker to be tripped remotely, which is commonly used for emergency shutdowns or automated control systems.

Which legacy Square D breaker does the HJA36100SA replace?

This PowerPacT H-frame breaker is the direct modern replacement for the legacy FA-frame FA361001021. Both are 100A, 3-pole, 600V I-Line breakers equipped with a 120VAC shunt trip, though the HJA model offers higher interrupting capacities.

Can the HJA36100SA be installed in a standard NEMA enclosure or unit-mount application?

No, this specific catalog number features an I-Line plug-in connection designed exclusively for Square D I-Line panelboards and switchboards. For unit-mount or standard enclosure applications, a unit-mount H-frame breaker with line and load lugs is required.

Are the trip settings adjustable on the HJA36100SA?

This breaker features a thermal-magnetic trip unit with fixed thermal and adjustable magnetic settings. While the continuous current overload protection is fixed at 100A, the instantaneous short-circuit magnetic trip threshold can be adjusted to properly coordinate with downstream devices or motor inrush currents.

What does the "J" in the HJA36100SA catalog number represent?

The "J" designates the interrupting rating tier within the Square D PowerPacT H-frame family. J-tier breakers provide high interrupting capacities, specifically 100kAIC at 240VAC and 65kAIC at 480VAC, making them suitable for systems with high available fault currents.

How is the HJA36100SA secured inside an I-Line panelboard?

As an I-Line style plug-in breaker, it features plug-on jaws that ratchet firmly onto the panel's vertical bus stack. It is then mechanically secured to the panelboard's mounting pan using a captive retaining screw, ensuring a safe and reliable connection without the need for line-side cables.

Can the HJA36100SA be used as a main breaker in an I-Line panel?

Yes, I-Line breakers can be used as either branch breakers or back-fed main breakers in Square D I-Line panelboards, provided the panel is configured to accept a back-fed main.

How can I manually test the mechanical tripping mechanism on the HJA36100SA?

The breaker is equipped with a push-to-trip button on the front face. Pressing this button manually exercises the tripping mechanism, moving the handle to the center tripped position to verify mechanical operation and ensure safety before maintenance.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.