Providing essential overcurrent protection, the Square D HJL36020 is a 20A, 3-pole PowerPacT MCCB. It features thermal-magnetic trip technology to deliver precise LI functions for industrial applications. This unit-mount device installs into switchboards, motor control centers, and control panels. It serves as a replacement for discontinued FCL36020 breakers. Capable of interrupting 65 kA at 480VAC, it ensures robust system safety and includes a highly visible Visi-Trip indicator.
What enclosures or panelboards accept the HJL36020?
The HJL36020 is a unit-mount breaker, meaning it mounts directly to a backpan or mounting plate using screws. It is typically used in industrial control panels, switchboards, and motor control centers. It is not compatible with I-Line plug-on panelboards.
Can the HJL36020 be reverse fed?
Yes. Square D PowerPacT H-frame thermal-magnetic breakers like the HJL36020 are suitable for reverse-fed applications.
What does the L in the HJL36020 catalog number indicate?
In the PowerPacT nomenclature, the L indicates the mounting and connection type. It signifies a unit-mount breaker with lugs on both the line and load sides. The H denotes the frame size, and the J denotes the interrupting rating.
Is the trip unit on the HJL36020 adjustable?
No. This breaker features a fixed thermal and fixed magnetic trip unit. It provides Long-Time and Instantaneous (LI) protection but does not have adjustable dials for the trip settings.
Does the HJL36020 provide ground fault protection?
No. The HJL36020 has an LI (Long-Time, Instantaneous) trip function. It does not include the G (Ground Fault) function. If ground fault protection is required, a different trip unit or an external equipment protection module is necessary.
What is the difference between the HJL36020 and the HDL36020 or HGL36020?
The difference is the interrupting rating. The HJL36020 has a J rating (65kA at 480V). The HDL36020 has a D rating (18kA at 480V), and the HGL36020 has a G rating (35kA at 480V). All three share the same physical dimensions and unit-mount design.
What is the recommended lug torque for the HJL36020?
Always refer to the breaker faceplate or instruction bulletin for exact torque specs, as they vary by wire size. Standard lugs typically require 44 lb-in (5 N.m) for 14 to 10 AWG wire, and up to 124 lb-in (14 N.m) for larger conductors like 8 to 3/0 AWG.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.