Schneider ElectricJDA36250U31X
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Square D |
|---|---|
| Series | JDA |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC |
| Amperage Range | 62.5-250A |
|---|
| Frame Type | JDA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Switchboards |
| Wire Gauge | 3/0 AWG - 350 kcmil (Al/Cu) |
| Max Wire | 350 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Auxiliary Switch, Alarm Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Micrologic 3.2S Trip Unit |
| Standards | CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CCC, CE, CSA, IEC, NOM, UKCA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Visual Trip Indicator, True RMS Sensing, Mercury Free, PVC Free |
Quantity
Re-Certified
Quantity
| Brand | Square D |
|---|---|
| Series | JDA |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC |
| Amperage Range | 62.5-250A |
|---|
| Frame Type | JDA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Switchboards |
| Wire Gauge | 3/0 AWG - 350 kcmil (Al/Cu) |
| Max Wire | 350 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Auxiliary Switch, Alarm Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Micrologic 3.2S Trip Unit |
| Standards | CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CCC, CE, CSA, IEC, NOM, UKCA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Visual Trip Indicator, True RMS Sensing, Mercury Free, PVC Free |
Schneider ElectricJDA36250U31X
| Brand | Square D |
|---|---|
| Series | JDA |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC |
| Amperage Range | 62.5-250A |
|---|
| Frame Type | JDA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Switchboards |
| Wire Gauge | 3/0 AWG - 350 kcmil (Al/Cu) |
| Max Wire | 350 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Available Options | Auxiliary Switch, Alarm Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Micrologic 3.2S Trip Unit |
| Standards | CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CCC, CE, CSA, IEC, NOM, UKCA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Visual Trip Indicator, True RMS Sensing, Mercury Free, PVC Free |
This I-Line plug-in circuit breaker is designed for use in Square D I-Line panelboards and switchboards. It mounts directly onto the interior bus stack.
Yes, Square D PowerPacT J-frame I-Line breakers can be installed in existing or older I-Line panelboards to upgrade or replace legacy breakers, provided the voltage and interrupting ratings meet your system requirements.
The D designates the interrupting rating of the breaker. For the PowerPacT J-frame series, the D-rating provides an interrupting capacity of 18kA at 480VAC and 25kA at 240VAC.
The U33X suffix indicates it is equipped with a Micrologic 3.2 S electronic trip unit. This provides adjustable LSI (Long-time, Short-time, and Instantaneous) protection functions for precise coordination.
The factory-installed AL250JD mechanical lugs accept aluminum or copper conductors ranging from 3/0 AWG to 350 kcmil.
No, the JDA36250U33X features an integrated I-Line plug-in mounting jaw on the line side, allowing it to connect directly onto the panelboard bus without additional mounting hardware.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.