Square D KH36090 Molded Case Circuit Breaker

  • 90A
  • 3 Pole
  • I-Line
Square D KH36090
Molded Case Circuit Breaker
Brand Square D
SKU KH36090
Select Item Condition
Earn 3778 SuperPoints
  • 90A
  • 3 Pole
  • I-Line

Quantity

Bulk Pricing
Send your parts list for a volume quote.
KH36090

Square D KH36090 - 90A 3 Pole Molded Case Circuit Breaker

New

$3,778.24 In Stock

Quantity

Similar Items

Description

Built for industrial power systems, the Square D KH36090 is a 90A, 3-pole molded case circuit breaker. It utilizes thermal-magnetic trip technology to deliver dependable long-time and instantaneous (LI) protection. The breaker installs into standard Square D I-Line panelboards and switchboards. When modernizing infrastructure, this unit is replaced by the JJA36090 model. With a 35kA interrupting rating at 480VAC, it handles demanding loads.

Specifications

Key specifications
Brand Square D
Part Number KH36090
Series KH
Amperage 90A
Poles 3
Mounting Style I-Line
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 65kA @ 240VAC, 35kA @ 480VAC, 25kA @ 600VAC, 10kA @ 250VDC
Fit and installation
Frame Type KH
Terminal Type Lugs
For Use With Square D I-Line Panelboards and Switchboards
Wire Gauge 4 AWG - 350 kcmil (Al/Cu)
Max Wire 350 kcmil
Min Wire 4 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Adjustable Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment
Accessories Load Side Lugs (AL250KA)
Standards CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval CSA, UL
Temp Rating 40C
Construction Features HACR Rated, High Interrupting Capacity

Product FAQs

6 answers
What panelboards accept the KH36090 circuit breaker?

This K-frame breaker is designed specifically for Square D I-Line panelboards and switchboards. It utilizes a plug-on jaw connection that mounts directly to the I-Line bus stack.

What is the direct replacement for the discontinued KH36090?

The legacy K-frame series has been superseded by the PowerPact J-frame. The manufacturer recommended replacement for this 90A I-Line breaker is catalog number JJA36090.

How does the LI trip unit function on this breaker?

The LI designation indicates Long-Time and Instantaneous trip functions. The thermal element provides fixed Long-Time overload protection, while the magnetic element offers an adjustable Instantaneous response to clear short circuits based on your specific coordination requirements.

What type of conductors can be terminated on the KH36090 lugs?

The standard mechanical lugs accept either aluminum or copper (Al/Cu) conductors ranging from 4 AWG to 350 kcmil.

Is this breaker suitable for DC power systems?

Yes, the KH36090 is rated for DC applications up to 250VDC, where it provides a 10kA interrupting capacity.

How is the I-Line connection secured during installation?

The breaker utilizes a plug-on jaw design that engages the I-Line bus stack. Once seated, a captive retaining screw on the breaker bracket must be torqued to the panelboard backpan to ensure a secure mechanical hold.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.

Reviews

5.0
Rated 5.0 out of 5 stars
Based on 1 review
Total 5 star reviews: 1 Total 4 star reviews: 0 Total 3 star reviews: 0 Total 2 star reviews: 0 Total 1 star reviews: 0
Rating
Ratings
1 review
  • DP
    Douglas P.
    Flag of United States
    Reviewing
    Square D KH36225 - 225A 3 Pole Molded Case Circuit Breaker
    I recommend this product
    Rated 5 out of 5 stars
    5/26/23
    I got it the next

    I got it the next day and it worked just like it should. Thank you