Schneider ElectricLJA36600U44X
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Schneider Electric |
|---|---|
| Series | LJA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 240-600A |
|---|
| Frame Type | L |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Square D I-Line Switchboards |
| Wire Gauge | (2) 3/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Trip Unit Model | MicroLogic 5.3A |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Communication Module |
|---|---|
| Accessories | MicroLogic 5.3A Trip Unit |
| Standards | CSA C22.2 No 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CCC, CE, CSA, IEC, NEMA, NOM, UL |
| Temp Rating | -25C to 70C |
| Construction Features | 80% Rated, Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Visual Trip Indicator, Phase Loss Protection |
Quantity
Re-Certified
Quantity
| Brand | Schneider Electric |
|---|---|
| Series | LJA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 240-600A |
|---|
| Frame Type | L |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Square D I-Line Switchboards |
| Wire Gauge | (2) 3/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Trip Unit Model | MicroLogic 5.3A |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Communication Module |
|---|---|
| Accessories | MicroLogic 5.3A Trip Unit |
| Standards | CSA C22.2 No 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CCC, CE, CSA, IEC, NEMA, NOM, UL |
| Temp Rating | -25C to 70C |
| Construction Features | 80% Rated, Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Visual Trip Indicator, Phase Loss Protection |
Schneider ElectricLJA36600U44X
Schneider ElectricLJA36400U43X
Schneider ElectricLJA36400CU43X
| Brand | Schneider Electric |
|---|---|
| Series | LJA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC |
| Amperage Range | 240-600A |
|---|
| Frame Type | L |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Square D I-Line Switchboards |
| Wire Gauge | (2) 3/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Electronic Trip |
|---|---|
| Trip Function Code | LSI |
| Trip Function | Long-Time, Short-Time, Instantaneous |
| Trip Adjustability | Adjustable |
| Trip Unit Model | MicroLogic 5.3A |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Communication Module |
|---|---|
| Accessories | MicroLogic 5.3A Trip Unit |
| Standards | CSA C22.2 No 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CCC, CE, CSA, IEC, NEMA, NOM, UL |
| Temp Rating | -25C to 70C |
| Construction Features | 80% Rated, Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Visual Trip Indicator, Phase Loss Protection |
The U43X suffix specifies that the breaker is equipped with a MicroLogic 5.3A (Ammeter) electronic trip unit, which provides adjustable Long-Time, Short-Time, and Instantaneous (LSI) protection.
This breaker features an I-Line mounting bracket and is specifically designed for installation in Square D I-Line panelboards and switchboards.
The mechanical lugs on the load side accept two 3/0 AWG to 500 kcmil aluminum or copper conductors per phase.
This circuit breaker has a standard continuous current rating of 80%.
This breaker features a standard ABC phase connection for integration with I-Line busbars.
No. Because it utilizes an I-Line plug-on connection for the line side and mechanical lugs for the load side, it is directional and cannot be reverse fed.
Yes, the integrated MicroLogic 5.3A electronic trip unit allows you to adjust the Long-Time, Short-Time, and Instantaneous (LSI) parameters to coordinate with your specific electrical system requirements.
The LJA36600U43X is built on the Schneider Electric and Square D PowerPacT L-Frame platform.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.