| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1115 |
| Series | THQL |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers, GE A-Series Panelboards |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment, Shunt Trip, Auxiliary Switch |
|---|---|
| Standards | HACR, NEMA AB 1, SWD, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1115-R |
| Series | THQL |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers, GE A-Series Panelboards |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment, Shunt Trip, Auxiliary Switch |
|---|---|
| Standards | HACR, NEMA AB 1, SWD, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break |
ABB / General ElectricTHQL1115ST1
ABB / General ElectricTHQL1120
ABB / General ElectricTHQL1120WL
ABB / General ElectricTHQL1125
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1115 |
| Series | THQL |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers, GE A-Series Panelboards |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment, Shunt Trip, Auxiliary Switch |
|---|---|
| Standards | HACR, NEMA AB 1, SWD, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break |
Yes. It mounts in standard 1-inch spaces in GE PowerMark Gold, ABB ReliaHome, and GE A-Series panelboards. ABB acquired GE Industrial Solutions and continues to manufacture these breakers, ensuring they are fully interchangeable.
The THQL1115 is a standard full-size breaker that requires a 1-inch space in the panel. The THQP115 is a half-size breaker that requires only a 1/2-inch space. While both are 15-amp, 1-pole breakers for compatible panels, they mount differently depending on the panel interior.
No, this is a standard thermal magnetic circuit breaker. It does not contain arc fault or ground fault circuitry. For combination arc fault protection, use catalog number THQL1115AF2. For ground fault protection, use THQL1115GF.
Yes. It carries both an HACR rating for heating, air conditioning, and refrigeration equipment, and an SWD (Switching Duty) rating, meaning it is approved for switching 120-volt fluorescent lighting circuits.
Yes. This standard non-interchangeable trip breaker is rated as suitable for reverse feed. If used as a back-fed main breaker, it must be secured to the load center with an approved hold-down retainer kit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.