ABB / General ElectricTHQL32045
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL32040 |
| Series | THQL |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Plug-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment |
|---|---|
| Standards | HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Internal Common Trip, Quick-Make/Quick-Break, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL32040-R |
| Series | THQL |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Plug-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment |
|---|---|
| Standards | HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Internal Common Trip, Quick-Make/Quick-Break, Reverse Feed |
ABB / General ElectricTHQL32045
ABB / General ElectricTHQL32035
ABB / General ElectricTHQL32050
ABB / General ElectricTHQL32050ST1
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL32040 |
| Series | THQL |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Plug-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Padlock Attachment |
|---|---|
| Standards | HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Internal Common Trip, Quick-Make/Quick-Break, Reverse Feed |
The recommended lug tightening torque depends on the wire gauge you are installing. For 8 AWG wire, torque the terminals to 40 in-lb. For 6 to 4 AWG, torque to 45 in-lb. For 3 AWG, the maximum torque is 50 in-lb.
No. While they may physically fit onto the bus bars of some competing 1-inch load centers, GE THQL breakers are not UL listed for use in Siemens, Square D, or Eaton panels. They must only be installed in compatible GE or ABB panels to maintain UL compliance and ensure safe operation.
Yes. Following ABB's acquisition of GE Industrial Solutions, THQL series breakers like the THQL32040 are fully compatible with legacy GE Powermark load centers as well as current ABB ReliaGear panels that accept standard 1-inch plug-on breakers.
The THQL32040 has an interrupting capacity of 10kAIC at 240V, which is standard for most residential and light commercial panels. The THHQL32040 shares the exact same form factor but features a higher interrupting rating of 22kAIC for applications that require greater fault current protection.
Yes. The box lug load terminals on this breaker are rated to accept 8 to 3 AWG wire for both copper (Cu) and aluminum (Al) conductors. Always use an approved oxide inhibitor when terminating aluminum wiring.
Yes. It is rated for a maximum of 240VAC, which makes it fully compatible with 240V Delta and 208Y/120V three-phase electrical systems.
Yes. Like most modern GE Q-Line breakers from 15 to 100 amps, the THQL32040 is UL Listed as an HACR type. This means it is rigorously tested and approved for use with heating, air conditioning, and refrigeration equipment.
Yes. This thermal-magnetic breaker is suitable for reverse feed applications, making it an option for back-feeding a panel from a secondary power source, such as a solar inverter or generator tie-in, provided a hold-down kit is used if required by local code.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.