| Brand | ABB / General Electric |
|---|---|
| Part Number | TJD432250WL |
| Series | TJD |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 20kA @ 250VDC |
| Frame Type | TJD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE J-Frame Enclosures, Switchboards |
| Wire Gauge | (1) 6 AWG-600 kcmil or (2) 2/0 AWG-250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Lugs (TCAL43) |
| Standards | UL 489, NEMA AB 1 |
| Approval | UL, CSA |
| Temp Rating | 40C |
| Construction Features | Non-Interchangeable Trip, Common Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJD432250WL-R |
| Series | TJD |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 20kA @ 250VDC |
| Frame Type | TJD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE J-Frame Enclosures, Switchboards |
| Wire Gauge | (1) 6 AWG-600 kcmil or (2) 2/0 AWG-250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Lugs (TCAL43) |
| Standards | UL 489, NEMA AB 1 |
| Approval | UL, CSA |
| Temp Rating | 40C |
| Construction Features | Non-Interchangeable Trip, Common Trip |
ABB / General ElectricTJD432300WL
ABB / General ElectricTJD432350WL
ABB / General ElectricTJD432400WL
ABB / General ElectricTJD432250
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJD432250WL |
| Series | TJD |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 20kA @ 250VDC |
| Frame Type | TJD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE J-Frame Enclosures, Switchboards |
| Wire Gauge | (1) 6 AWG-600 kcmil or (2) 2/0 AWG-250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Lugs (TCAL43) |
| Standards | UL 489, NEMA AB 1 |
| Approval | UL, CSA |
| Temp Rating | 40C |
| Construction Features | Non-Interchangeable Trip, Common Trip |
This feed-thru breaker is designed for installation in GE J-Frame enclosures and compatible industrial switchboards.
Yes, the WL suffix in the catalog number indicates that both line and load side lugs are factory installed. The lugs accept either one 6 AWG to 600 kcmil wire or two 2/0 AWG to 250 kcmil wires, and are rated for copper or aluminum conductors.
Yes, in addition to its 240VAC rating, this breaker is rated for use on 250VDC systems with a maximum interrupting capacity of 20kA.
No, this breaker features a fixed thermal and fixed magnetic trip unit. The Long-Time and Instantaneous (LI) protection parameters are factory set and cannot be modified in the field.
ABB acquired GE Industrial Solutions in 2018. As a result, newly manufactured TJD432250WL breakers may feature ABB branding. The physical dimensions, fit, and internal components remain identical to the legacy GE versions.
It features a unit mount, feed-thru design. It bolts directly to the enclosure or mounting pan rather than plugging onto a busbar, making it suitable for standalone enclosures and switchboards.
It uses a thermal magnetic trip mechanism to protect electrical circuits. The thermal element responds to sustained overloads, while the magnetic element trips instantaneously during high-current short circuits.
No, the thermal magnetic trip unit is fixed and non-interchangeable. If your application requires a different amperage rating or trip characteristic, you must replace the entire circuit breaker.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.