| Brand | ABB / General Electric |
|---|---|
| Part Number | TJK636400WL |
| Series | TJK |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC, 20kA @ 500VDC |
| Frame Type | TJK |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (2) 4/0 AWG-350 kcmil (Cu) or (2) 300-500 kcmil (Al) |
| Max Wire | 500 kcmil |
| Min Wire | 4/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Includes Lugs (TCAL63) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated, Trip-Free Mechanism, Quick-Make/Quick-Break |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJK636400WL-R |
| Series | TJK |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC, 20kA @ 500VDC |
| Frame Type | TJK |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (2) 4/0 AWG-350 kcmil (Cu) or (2) 300-500 kcmil (Al) |
| Max Wire | 500 kcmil |
| Min Wire | 4/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Includes Lugs (TCAL63) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated, Trip-Free Mechanism, Quick-Make/Quick-Break |
ABB / General ElectricTJK436400WL
ABB / General ElectricTJK436400
ABB / General ElectricTJK636450
ABB / General ElectricTJK636450WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJK636400WL-R |
| Series | TJK |
| Amperage | 400A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC, 20kA @ 500VDC |
| Frame Type | TJK |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (2) 4/0 AWG-350 kcmil (Cu) or (2) 300-500 kcmil (Al) |
| Max Wire | 500 kcmil |
| Min Wire | 4/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Includes Lugs (TCAL63) |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated, Trip-Free Mechanism, Quick-Make/Quick-Break |
The WL suffix indicates that the breaker is supplied with factory-installed copper and aluminum (Cu/Al) line and load lugs.
Both are 600V-rated J-frame breakers. The primary difference is that the TJK frame features an interchangeable trip unit, whereas the TJJ frame has a fixed, non-interchangeable trip unit.
Yes, this breaker features an adjustable magnetic trip for setting the instantaneous short-circuit pickup level. The thermal overload protection is fixed.
The included lugs accept two 4/0 AWG to 350 kcmil copper conductors, or two 300 kcmil to 500 kcmil aluminum conductors per phase.
Yes, the TJK636400WL is rated for DC systems up to 500VDC. It provides a 20kA interrupting capacity at both 250VDC and 500VDC.
This unit-mount J-frame breaker is designed for installation in standalone enclosures, switchboards, and motor control centers.
This breaker is built on the GE J-frame platform. Specifically, it uses the 400A frame size, which accommodates trip units ranging from 125A to 400A.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.