ABB / General ElectricTKMA836800WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA31200WL |
| Series | TKMA |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Frame Type | TKM |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | (4) 250-350 kcmil (Cu) or (4) 250-500 kcmil (Al) |
| Max Wire | 500 kcmil |
| Min Wire | 250 kcmil |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL121) |
| Standards | UL 489, NEMA AB-1, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA31200WL-R |
| Series | TKMA |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Frame Type | TKM |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | (4) 250-350 kcmil (Cu) or (4) 250-500 kcmil (Al) |
| Max Wire | 500 kcmil |
| Min Wire | 250 kcmil |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL121) |
| Standards | UL 489, NEMA AB-1, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, Reverse Feed |
ABB / General ElectricTKMA836800WL
ABB / General ElectricTKMA836600WL
ABB / General ElectricTKMA836500WL
ABB / General ElectricTKMA836450WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA31200WL-R |
| Series | TKMA |
| Amperage | 1200A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Frame Type | TKM |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | (4) 250-350 kcmil (Cu) or (4) 250-500 kcmil (Al) |
| Max Wire | 500 kcmil |
| Min Wire | 250 kcmil |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL121) |
| Standards | UL 489, NEMA AB-1, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, Reverse Feed |
The "WL" suffix designates that the breaker is supplied with factory-installed line and load lugs. GE circuit breaker models ordered without this suffix typically do not include line-side lugs.
This legacy K-Frame molded case circuit breaker is engineered for unit-mount installations in General Electric switchboards, motor control centers (MCCs), and individual enclosures.
The included lugs are configured to accept four wires per phase. They accommodate wire sizes ranging from (4) 250 to 350 kcmil for copper (Cu) conductors or (4) 250 to 500 kcmil for aluminum (Al) conductors.
Yes, this breaker uses an interchangeable thermal-magnetic trip unit featuring a fixed thermal element for long-time overcurrents and an adjustable magnetic element to dial in the instantaneous trip threshold.
The TKMA series features a standard interrupting capacity, rated at 30kAIC at 480VAC. The THKMA series is the high-interrupting capacity version of the same K-Frame, which bumps the interrupting rating to 35kAIC or higher at 480VAC.
Yes, this thermal-magnetic K-Frame breaker is rated for reverse-feed applications. Installers must still verify that the specific panelboard or enclosure is listed to accept reverse-fed breakers before installation.
No, the TKMA31200WL features an interchangeable trip unit design. This allows the thermal-magnetic module to be replaced without removing the entire circuit breaker frame from the bus structure.
No, the TKMA31200WL uses an LI (Long-Time and Instantaneous) trip unit. It provides standard thermal overload and magnetic short-circuit protection, but does not include integrated ground fault (G) protection capabilities.
Installation must be performed by a qualified electrician. Always completely de-energize, lock out, and tag out (LOTO) the switchgear power feed and verify zero voltage with a properly rated meter before accessing any busbars or terminals.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.