ABB / General ElectricTKMA836450WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA836500WL |
| Series | TKMA |
| Amperage | 500A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Switchboards, Motor Control Centers, GE CCB Panelboards, GE AV1 Panelboards |
| Wire Gauge | (3) 3/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA836500WL-R |
| Series | TKMA |
| Amperage | 500A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Switchboards, Motor Control Centers, GE CCB Panelboards, GE AV1 Panelboards |
| Wire Gauge | (3) 3/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated |
ABB / General ElectricTKMA836450WL
ABB / General ElectricTKMA836600WL
ABB / General ElectricTKMA836800WL
ABB / General ElectricTHKMA836500
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA836500WL |
| Series | TKMA |
| Amperage | 500A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Switchboards, Motor Control Centers, GE CCB Panelboards, GE AV1 Panelboards |
| Wire Gauge | (3) 3/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 3/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, IEC, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated |
The "WL" suffix indicates that the circuit breaker is supplied from the factory with both line and load lugs included. If ordered without this suffix, the breaker frame is supplied without lugs.
Both are 500A, 3-pole K-Frame circuit breakers, but the THKMA series features a higher short-circuit interrupting rating (AIC) than the standard TKMA series. They share the same physical footprint and mounting requirements.
Yes, this breaker is part of the GE K1200 line and features an interchangeable thermal-magnetic trip unit. This allows the trip unit to be swapped or replaced without removing the entire breaker frame from the panel.
It utilizes a thermal-magnetic trip unit with a fixed thermal element for long-time overload protection and an adjustable magnetic element for instantaneous short-circuit protection.
This unit-mount K-Frame breaker is designed for installation in GE switchboards, motor control centers, GE CCB panelboards, and GE AV1 panelboards.
The factory-installed lugs accept up to three conductors per phase, supporting 3/0 AWG to 500 kcmil aluminum or copper (Al/Cu) wire.
Yes, since the GE K-Frame is a legacy product, it can be upgraded or replaced using the modern ABB Tmax XT5 series circuit breakers along with the appropriate retrofit kit.
A feed-thru connection means the breaker is designed to be hardwired on both the line and load sides using the provided lugs, rather than plugging directly into a busbar system.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.