ABB / General ElectricTKMA836500WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA836600WL |
| Series | TKMA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Switchboards, Motor Control Centers, GE CCB Panelboards, GE AV1 Panelboards |
| Wire Gauge | (2) 2/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 2/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA836600WL-R |
| Series | TKMA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Switchboards, Motor Control Centers, GE CCB Panelboards, GE AV1 Panelboards |
| Wire Gauge | (2) 2/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 2/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated |
ABB / General ElectricTKMA836500WL
ABB / General ElectricTKMA836450WL
ABB / General ElectricTKMA836800WL
ABB / General ElectricTHKMA836600
| Brand | ABB / General Electric |
|---|---|
| Part Number | TKMA836600WL-R |
| Series | TKMA |
| Amperage | 600A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 42kA @ 240VAC, 30kA @ 480VAC, 22kA @ 600VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE Switchboards, Motor Control Centers, GE CCB Panelboards, GE AV1 Panelboards |
| Wire Gauge | (2) 2/0 AWG - 500 kcmil (Al/Cu) |
| Max Wire | 500 kcmil |
| Min Wire | 2/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Interchangeable Trip Unit, HACR Rated |
This K-frame breaker is designed for use in legacy GE switchboards, motor control centers, and GE CCB or AV1 panelboards.
The factory lugs accept two conductors per phase, ranging from 2/0 AWG to 500 kcmil. They are rated for both aluminum and copper wiring.
Yes, this thermal-magnetic breaker features a fixed thermal element for overload protection and an adjustable magnetic element. The magnetic setting allows you to tune the instantaneous trip response to accommodate specific motor inrush currents or coordination requirements.
ABB acquired GE Industrial Solutions in 2018. Legacy GE molded case circuit breakers, including the TKMA series, are now manufactured and supported under the ABB brand portfolio.
This is a unit-mount, feed-thru circuit breaker. It bolts directly to the enclosure backpan or mounting surface and connects to the bus or load via cable lugs, rather than plugging directly onto a panelboard bus.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.