| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC1115GF |
| Series | THQC |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | DIN Rail |
| Voltage | 120VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC |
| Frame Type | THQC |
|---|---|
| Terminal Type | Lugs |
| For Use With | DIN Rail Systems, OEM Panels, Enclosures, Control Panels |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, UL 943, SWD |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break, Visual Trip Indicator |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC1115GF-R |
| Series | THQC |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | DIN Rail |
| Voltage | 120VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC |
| Frame Type | THQC |
|---|---|
| Terminal Type | Lugs |
| For Use With | DIN Rail Systems, OEM Panels, Enclosures, Control Panels |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, UL 943, SWD |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break, Visual Trip Indicator |
ABB / General ElectricTHQC1120GF
ABB / General ElectricTHQC1120GFT
ABB / General ElectricTHQC1130GF
ABB / General ElectricTHQC1130GFT
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC1115GF |
| Series | THQC |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | DIN Rail |
| Voltage | 120VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC |
| Frame Type | THQC |
|---|---|
| Terminal Type | Lugs |
| For Use With | DIN Rail Systems, OEM Panels, Enclosures, Control Panels |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, UL 943, SWD |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break, Visual Trip Indicator |
It features a plug-in connection designed for DIN rail systems, OEM panels, and control enclosures, rather than standard residential load centers.
Yes. Following the acquisition of GE Industrial Solutions by ABB, Q-Line breakers may carry either ABB or General Electric branding. They share the exact same specifications, form factor, and THQC catalog number.
This breaker is equipped with a pigtail neutral. The coiled white pigtail wire must be routed and secured directly to the neutral bus bar in your panel for the ground fault circuit interrupter (GFCI) to function correctly.
Yes, the terminal lugs are dual-rated for both conductor materials. They accept 14 AWG to 8 AWG copper wire and 12 AWG to 8 AWG aluminum wire. Always ensure proper torque is applied to the lugs during installation to prevent arcing.
It utilizes a fixed thermal-magnetic trip mechanism with Long-Time (L) and Instantaneous (I) functions for overcurrent and short circuit protection, plus a Ground-Fault (G) function to protect personnel from electrical shock.
This GFCI breaker provides Class A ground fault protection, meaning it is designed to trip when it detects a ground fault leakage current of 5mA. This meets NEC requirements for personnel protection in wet and damp locations.
Yes, this breaker is HACR rated, meaning it is approved for use with compatible heating, air conditioning, and refrigeration equipment that requires a 15A ground fault circuit interrupter.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.