Eaton / Cutler-HammerGHB3060S1
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3060 |
| Series | GHB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line C Panelboards, Series C Panelboards, Westinghouse PRL2 Panelboards |
| Wire Gauge | #10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3060-R |
| Series | GHB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line C Panelboards, Series C Panelboards, Westinghouse PRL2 Panelboards |
| Wire Gauge | #10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Eaton / Cutler-HammerGHB3060S1
Eaton / Cutler-HammerGHB3070S1
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3060-R |
| Series | GHB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line C Panelboards, Series C Panelboards, Westinghouse PRL2 Panelboards |
| Wire Gauge | #10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Yes. Eaton acquired the Westinghouse distribution equipment line and the Cutler-Hammer brand. A new Eaton GHB breaker is an exact drop-in replacement for vintage Westinghouse or Cutler-Hammer GHB breakers with the same specifications.
This G-frame bolt-on breaker is designed for use in Eaton Pow-R-Line C, Pow-R-Line 2 (PRL2), and Pow-R-Line 3a (PRL3a) panelboards. It will also fit older legacy Westinghouse Series C panelboards that accept standard bolt-on G-frame breakers.
A 480Y/277V slash rating indicates the breaker is only approved for solidly grounded wye systems where the line-to-ground voltage does not exceed 277V. It cannot be used on corner-grounded or ungrounded 480V delta systems, because single-pole fault clearing could expose the breaker to the full 480V phase-to-phase voltage.
According to Eaton specifications for G-frame breakers, the terminal screw torque depends on the wire size. For #10 AWG wire, torque to 20 lb-in. For #8 AWG, torque to 40 lb-in. For #6 to #4 AWG, torque to 45 lb-in. For #3 to 1/0 AWG, torque to 50 lb-in. Always verify with the breaker nameplate before final installation.
Yes, the GHB3060 is suitable for reverse feed applications. Because it uses fixed thermal-magnetic trip units and has no internal line or load directional restrictions, you can safely land the incoming supply power on either the top or bottom terminals.
No. Eaton BR and CH series are plug-on breakers intended for residential and light commercial loadcenters. The GHB is a bolt-on molded case circuit breaker specifically built for Pow-R-Line commercial and industrial panelboards. They have completely different bus mounting styles and are not interchangeable.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.