Eaton / Cutler-HammerGHB3050S1
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3050 |
| Series | GHB |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Eaton Series C Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3050-R |
| Series | GHB |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Eaton Series C Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Eaton / Cutler-HammerGHB3050S1
Eaton / Cutler-HammerGHB3060S1
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3050 |
| Series | GHB |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Eaton Series C Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
The GHB3050 is designed for use in Eaton Pow-R-Line 2 (PRL2, PRL2a) and Pow-R-Line 3a panelboards, as well as Eaton Series C enclosures and switchboards. It typically mounts horizontally and bolts directly to the panel bus.
Yes. Eaton acquired both the Cutler-Hammer and Westinghouse distribution equipment lines. The current Eaton GHB3050 is a direct, drop-in replacement for older Cutler-Hammer and Westinghouse breakers bearing the exact same catalog number.
No. The GHB3050 carries a 480Y/277V slash rating. This indicates it is only approved for use on solidly grounded Wye systems where the voltage to ground does not exceed 277 volts. It must not be applied on ungrounded or corner-grounded 480V Delta networks.
Yes. Eaton G-frame circuit breakers, including the GHB3050, are non-interchangeable trip breakers that are fully approved and suitable for reverse feed use.
Underwriters Laboratories (UL) standards require internal accessories for GHB breakers to be factory-installed in order to maintain the breaker's UL 489 listing. The breaker is factory sealed, so field installation of internal accessories will void this certification.
No. The GHB3050 features a non-interchangeable thermal-magnetic trip unit with fixed thermal and fixed magnetic settings. The long-time overload protection is permanently set to 50 amps, and the instantaneous short-circuit trip point is set at a predetermined factory level that cannot be modified.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.