Eaton / Cutler-HammerCHFN130GF
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH130GFI |
| Series | CH |
| Amperage | 30A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Type CH Load Centers |
| Wire Gauge | 14-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH130GFI-R |
| Series | CH |
| Amperage | 30A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Type CH Load Centers |
| Wire Gauge | 14-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated |
Eaton / Cutler-HammerCHFN130GF
Eaton / Cutler-HammerCHFN115GF
Eaton / Cutler-HammerCHFN230GF
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CH130GFI-R |
| Series | CH |
| Amperage | 30A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Type CH Load Centers |
| Wire Gauge | 14-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated |
This breaker is designed exclusively for Eaton and Cutler-Hammer Type CH load centers. It requires a 3/4-inch space per pole and will not fit Type BR panels, which use a 1-inch spacing.
This is a Class A GFCI breaker, which provides personnel protection by tripping when it detects a ground fault leakage current of 5mA.
This model features a pigtail neutral. The coiled white wire must be connected directly to the panel neutral bus bar for the GFCI circuitry to function properly.
Yes, the CH130GFI has been superseded by the CHFN130GF in newer Eaton catalog revisions. Both are 30A, 1-pole GFCI breakers with a pigtail neutral for Type CH panels.
No. As a 1-pole breaker, it provides 120V. A 240V load requiring ground fault protection would need a 2-pole GFCI breaker.
Eaton Type CH breakers feature a mechanism that trips the handle fully to the OFF position, rather than a middle position, making it easy to identify a tripped circuit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.