Eaton / Cutler-HammerBRN120A1CS
Quantity
New
Quantity
Eaton / Cutler-HammerBRN120A1CS
Eaton / Cutler-HammerBRN115A1CS
Eaton / Cutler-HammerBRAFGF120
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | BRN |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC |
| Frame Type | BRN |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Type BR Load Centers |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | Dual Function (AFCI/GFCI) |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | UL 489, UL 943, UL 1699 |
| Approval | UL |
| Temp Rating | 40C |
| Construction Features | Trip-to-Center, Self-Test, Visual Trip Indicator, Short Body |
It is designed specifically for Eaton, Cutler-Hammer, and Bryant Type BR load centers that use a 1-inch per pole plug-on format. It is not interchangeable with Type CH panels or other manufacturer boards.
The BRN120DF features a pigtail neutral. The installer must land the attached white pigtail wire directly onto the neutral bus bar in the panel. It is not designed for Plug-On Neutral (PON) configurations.
A dual function breaker integrates both Arc Fault Circuit Interrupter (AFCI) and Ground Fault Circuit Interrupter (GFCI) protection into a single device. This combination satisfies NEC requirements for branch circuits that need both protections, such as those in kitchens and laundry areas.
Turn the tripped breaker back to the ON position. The red diagnostic LED on the face of the breaker will blink a specific pattern, from 1 to 6 times, to indicate the cause of the trip (such as a ground fault or series arc). This sequence will repeat 30 times.
The LIG designation indicates the specific thermal-magnetic trip capabilities: Long-Time (for standard overcurrent overloads), Instantaneous (for sudden short circuits), and Ground Fault (for leakage current to ground).
Yes. Eaton acquired Cutler-Hammer and continues to manufacture the BR product line. This breaker can safely replace older Cutler-Hammer or Bryant BR series breakers in listed Type BR load centers.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.