Eaton / Cutler-HammerBABRP1020
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB1020 |
| Series | BAB |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC, 24VDC, 48VDC, 62.5VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC, 5kA @ 24VDC, 5kA @ 48VDC, 3.8kA @ 62.5VDC |
| Frame Type | BAB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Al/Cu) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Extended Tang Line Terminal |
| Standards | HACR, SWD, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB1020-R |
| Series | BAB |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC, 24VDC, 48VDC, 62.5VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC, 5kA @ 24VDC, 5kA @ 48VDC, 3.8kA @ 62.5VDC |
| Frame Type | BAB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Al/Cu) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Extended Tang Line Terminal |
| Standards | HACR, SWD, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBABRP1020
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB1020-R |
| Series | BAB |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC, 24VDC, 48VDC, 62.5VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC, 5kA @ 24VDC, 5kA @ 48VDC, 3.8kA @ 62.5VDC |
| Frame Type | BAB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards |
| Wire Gauge | 14-4 AWG (Al/Cu) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Extended Tang Line Terminal |
| Standards | HACR, SWD, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
No. The BAB1020 is an industrial bolt-on circuit breaker designed specifically for Eaton Pow-R-Line panelboards, as well as compatible legacy Westinghouse and Bryant panels. It will not fit in standard residential load centers that require plug-on BR or CH series breakers.
It is designed for Pow-R-Line enclosures configured for 1-inch Quicklag bolt-on branch breakers. This most commonly includes the PRL1a and PRL1a-LX series panelboards.
Yes. Eaton acquired the Westinghouse distribution equipment line. A modern Eaton BAB1020 is a direct, exact drop-in replacement for legacy Westinghouse and Cutler-Hammer breakers with the same catalog number.
Yes. This component serves as an exact replacement for older, discontinued QNBL1020 models used in vintage bolt-on panelboards.
Yes. It carries an SWD rating, meaning it is approved for regularly switching fluorescent lighting loads on and off. It is also HACR certified for safely protecting heating, air conditioning, and refrigeration equipment circuits.
No. While both are Eaton bolt-on circuit breakers, they belong to different frames and fit different panelboards. The BAB series fits 1-inch Quicklag chassis (like the PRL1a), while the GHB series fits 277/480V rated panelboards (like the PRL2a) and has a completely different physical footprint.
No. The BAB1020 provides standard thermal-magnetic branch circuit protection against overloads and short circuits. It does not include built-in AFCI or GFCI protection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.