| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDD |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 125VDC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 10kA @ 125VDC, 10kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Panelboards, Switchboards |
| Wire Gauge | 4 AWG - 4/0 AWG (Al/Cu) |
| Max Wire | 4/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle |
|---|---|
| Accessories | Load Side Lugs Included (PDG2X3TA225) |
| Standards | CSA, RoHS, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, RoHS Compliant, Dual Rated (AC/DC) |
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDD |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 125VDC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 10kA @ 125VDC, 10kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Panelboards, Switchboards |
| Wire Gauge | 4 AWG - 4/0 AWG (Al/Cu) |
| Max Wire | 4/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle |
|---|---|
| Accessories | Load Side Lugs Included (PDG2X3TA225) |
| Standards | CSA, RoHS, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, RoHS Compliant, Dual Rated (AC/DC) |
Eaton/Cutler-HammerPDG23G0225TFFL
Eaton / Cutler-HammerPDG33G0225TFAJ
Eaton / Cutler-HammerPDG23G0225TFFJ
Eaton / Cutler-HammerPDG23M0225TFFL
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | PDD |
| Amperage | 225A |
| Poles | 3 |
| Mounting Style | Panel Mount |
| Voltage | 240VAC, 125VDC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 10kA @ 125VDC, 10kA @ 250VDC |
| Frame Type | Complete Breaker |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Power Defense Panelboards, Switchboards |
| Wire Gauge | 4 AWG - 4/0 AWG (Al/Cu) |
| Max Wire | 4/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle |
|---|---|
| Accessories | Load Side Lugs Included (PDG2X3TA225) |
| Standards | CSA, RoHS, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, RoHS Compliant, Dual Rated (AC/DC) |
This Frame 2 breaker installs directly into Eaton Power Defense panelboards and switchboards. With the correct retrofit kit, it can also serve as a direct replacement for legacy F-Frame (FD) circuit breakers.
"PDD" designates a UL/CSA-rated Power Defense breaker. "2" is the frame size. "3" indicates three poles. "G" specifies the 65kAIC rating at 240VAC. "0225" is the 225A capacity. "TFF" stands for a fixed thermal and fixed magnetic trip unit, and "L" means standard load lugs are included.
The included load-side lugs accommodate conductors ranging from 4 AWG to 4/0 AWG. The terminals are dual-rated for either aluminum or copper wire.
Yes, the thermal-magnetic trip unit allows this breaker to be applied in DC circuits. It carries a 10kAIC interrupting rating for both 125VDC and 250VDC applications.
No, the TFF designation means both the thermal (long-time) and magnetic (instantaneous) trip functions are fixed. If your application requires adjustable trip settings, you will need a breaker with an electronic trip unit or an adjustable thermal-magnetic model.
Yes, this unit is shipped as a complete breaker, meaning the frame, thermal-magnetic trip unit, and standard load lugs are fully assembled and ready for installation.
Always de-energize the panelboard or switchboard before installation. Verify that the bolt-on connections are properly seated and secured to the busbar to prevent arcing or overheating under load.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.