ABB / General ElectricTEB122100
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB122090 |
| Series | TEB |
| Amperage | 90A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 120/240VAC, 125/250VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 120/240VAC, 5kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, NEMA AB-1 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB122090-R |
| Series | TEB |
| Amperage | 90A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 120/240VAC, 125/250VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 120/240VAC, 5kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, NEMA AB-1 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTEB122100
ABB / General ElectricTEB122080
ABB / General ElectricTEB122070
ABB / General ElectricTEB122060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB122090-R |
| Series | TEB |
| Amperage | 90A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 120/240VAC, 125/250VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 120/240VAC, 5kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, NEMA AB-1 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism |
This E-frame breaker features a bolt-on connection. It is designed to bolt directly to the bus in GE A-Series and Spectra Series panelboards, as well as compatible modular metering stacks.
Yes, the TEB122090 is a direct replacement for the obsolete GE TE122090 circuit breaker. It fits the exact same E-frame footprint in existing panelboards.
Yes, this 90A breaker is HACR rated, making it suitable for use with heating, air conditioning, and refrigeration equipment.
Yes, all GE TEB series breakers are suitable for reverse feed applications, allowing flexibility in how line and load connections are wired.
This breaker belongs to the GE E150 line, commonly referred to as an E-frame. It shares the same 1.375-inch per-pole spacing as TED and THED circuit breakers.
The breaker utilizes a fixed thermal-magnetic trip unit. The thermal element provides a long-time delay for overload protection, while the magnetic element delivers instantaneous tripping during short circuits. The trip unit is non-interchangeable.
The terminals on this 90A breaker are dual-rated for 60/75 degrees Celsius. This allows installers to size copper or aluminum conductors based on the 75-degree column in the NEC, provided the connected equipment is also rated for 75 degrees.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.