ABB / General ElectricTEB132100
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB132090 |
| Series | TEB |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 5kA @ 250VDC |
| Frame Type | TEB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 6 AWG - 1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Lug |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB132090 |
| Series | TEB |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 5kA @ 250VDC |
| Frame Type | TEB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 6 AWG - 1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Lug |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTEB132100
ABB / General ElectricTEB132070
ABB / General ElectricTEB132060
ABB / General ElectricTEB132045
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB132090 |
| Series | TEB |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 5kA @ 250VDC |
| Frame Type | TEB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 6 AWG - 1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Lug |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
The TEB132090 is a bolt-on breaker designed specifically for GE A-Series panelboards. It is not compatible with standard GE residential load centers that require THQL plug-on or THQB 1-inch bolt-on breakers.
Yes, in addition to its standard 240VAC rating at 10kAIC, the TEB132090 is rated for use in 250VDC applications with an interrupting capacity of 5kAIC.
The standard load lugs on this breaker accept 6 AWG through 1/0 AWG wire. The terminals are dual-rated for both copper (Cu) and aluminum (Al) conductors.
The TEB132090 is part of the legacy GE E150 frame product line. This family includes TEB, TED, and THED thermal-magnetic circuit breakers, which share identical physical dimensions and mountings for breakers up to 150 amps.
No, the TEB132090 features a fixed thermal-magnetic trip unit. Both the long-time (overload) and instantaneous (short-circuit) trip functions are factory-set and non-interchangeable.
Yes, GE TEB, TED, and THED molded case circuit breakers are suitable for reverse feed applications. They can be back-fed without affecting the performance of the thermal-magnetic trip unit.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.