| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124045-R |
| Series | TED |
| Amperage | 45A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | TED |
| Amperage | 45A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
ABB / General ElectricTED124050
ABB / General ElectricTED124040
ABB / General ElectricTED124035
ABB / General ElectricTED124060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124045-R |
| Series | TED |
| Amperage | 45A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
This E-frame breaker is designed for installation in GE A-Series and GE Spectra Series panelboards.
Yes, mounting a TED frame breaker into a Spectra Series panelboard requires a dedicated mounting hardware kit, such as the TED1DPK, to make the bus connections.
Yes, GE TED frame molded case circuit breakers do not have line and load restrictions and are suitable for reverse feed applications.
Yes, in addition to its AC ratings, this thermal magnetic breaker is rated for use in DC systems up to 250VDC with a 10kAIC interrupting capacity.
GE Industrial Solutions was acquired by ABB, making the TED frame a legacy product. The official modern replacement is the ABB Tmax XT1 series, though upgrading requires a specific retrofit kit for existing panels.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.