| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124060 |
| Series | TED |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124060-R |
| Series | TED |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTED124070
ABB / General ElectricTED124050
ABB / General ElectricTED124045
ABB / General ElectricTED124080
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124060 |
| Series | TED |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
The WL suffix in GE catalog numbers indicates that the circuit breaker comes factory-equipped with copper/aluminum (Cu/Al) line and load lugs. Both part numbers refer to the same 60-amp E150 frame breaker, but the TED124060WL explicitly includes the terminal lugs.
This E-frame molded case circuit breaker is designed for bolt-on installation in GE A-Series panelboards and Spectra Series switchboards or panelboards. It is also commonly used in standalone enclosed circuit breaker applications.
Yes, all GE TED series circuit breakers above 10 amps, including this 60-amp model, are UL listed as HACR type for use with heating, air conditioning, and refrigeration equipment.
Yes, GE TEB, TED, and THED series molded case circuit breakers are suitable for reverse feed applications. This allows the breaker to be back-fed when used as a main breaker or in specific generator setups.
Yes, the THED series is the high-interrupting (Hi-Break) version of the standard TED series. Both share the same E150 frame footprint and mounting dimensions, allowing a THED breaker to directly replace a TED breaker when a higher fault current rating is required.
This is a unit-mount, bolt-on circuit breaker. It secures directly to the panelboard bus or mounting bracket using bolts, rather than snapping or plugging into place.
No, this breaker features a non-interchangeable thermal magnetic trip unit with fixed long-time and instantaneous (LI) functions. The trip settings cannot be adjusted in the field.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.