| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1120 |
| Series | THQL |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers, GE A-Series Panelboards |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Standards | UL 489, CSA C22.2 No. 5, HACR, SWD |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1120-R |
| Series | THQL |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers, GE A-Series Panelboards |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Standards | UL 489, CSA C22.2 No. 5, HACR, SWD |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break |
ABB / General ElectricTHQL1120WL
ABB / General ElectricTHQL1125
ABB / General ElectricTHQL1115
ABB / General ElectricTHQL1115ST1
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1120-R |
| Series | THQL |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers, GE A-Series Panelboards |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Standards | UL 489, CSA C22.2 No. 5, HACR, SWD |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break |
While both are Q-Line breakers, they are not strictly interchangeable for the same panel slots. The THQL1120 is a standard 1-inch wide full-size breaker, whereas THQP breakers are 1/2-inch wide half-size units. Always verify your load center's label to see which breaker types are permitted and how they fit your specific busbar configuration.
Yes, the THQL1120 is backward compatible with most legacy GE PowerMark Gold and A-Series panelboards that accept standard 1-inch plug-on Q-Line breakers. However, you should consult the interior label of your panel to confirm THQL is an approved replacement type.
ABB acquired GE Industrial Solutions, so the THQL circuit breaker line is now manufactured by ABB. It retains the same THQL1120 catalog number, physical dimensions, and UL listings as the original GE product, making it a direct drop-in replacement for older GE-branded units.
Yes, 15A and 20A single-pole THQL breakers carry an SWD (Switching Duty) rating. This means the THQL1120 is certified to be used safely as a switch for standard 120V fluorescent lighting circuits without damaging the breaker mechanism.
Yes, the THQL1120 is HACR rated. This indicates it is UL-approved for use with Heating, Air Conditioning, and Refrigeration equipment that requires this specific overcurrent protection designation.
Like most standard thermal-magnetic breakers, the THQL1120 is rated for 80 percent continuous load. For continuous applications operating for three hours or more, the sustained load should not exceed 16 amps.
No, the THQL1120 is a standard thermal-magnetic circuit breaker designed solely to protect against short circuits and overloads. It does not include ground-fault (GFCI) or arc-fault (AFCI) protection features.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.