ABB / General ElectricTHQL2120GF1
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL2115GF |
| Series | THQL |
| Amperage | 15A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | GE Q-Line Load Centers, PowerMark Gold Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFCI |
|---|---|
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | HACR, UL 489, UL 943, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL2115GF-R |
| Series | THQL |
| Amperage | 15A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | GE Q-Line Load Centers, PowerMark Gold Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFCI |
|---|---|
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | HACR, UL 489, UL 943, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break |
ABB / General ElectricTHQL2120GF1
ABB / General ElectricTHQL2120GFT
ABB / General ElectricTHQL2125GFT
ABB / General ElectricTHQL2130GFT
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL2115GF-R |
| Series | THQL |
| Amperage | 15A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | GE Q-Line Load Centers, PowerMark Gold Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFCI |
|---|---|
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | HACR, UL 489, UL 943, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break |
No, the THQL2115GF is a full-size 1-inch per pole breaker. It requires two standard 1-inch spaces in a GE Q-Line or PowerMark Gold load center and will not fit in half-inch THQP slots.
No, the THQL2115GF uses a traditional pigtail neutral. It is compatible with standard GE Q-Line and PowerMark Gold panels and does not require a specialized plug-on neutral bus.
It provides Class A ground fault protection, which trips at a 5mA threshold to protect personnel from electrical shock in wet locations.
For a dedicated 240V load without a load neutral, connect the two hot wires to the breaker terminals. You must still connect the breaker's white pigtail wire to the panel neutral bus bar to power the internal GFCI circuitry.
Yes, this 2-pole GFCI breaker can protect a multi-wire branch circuit with a shared neutral. The shared load neutral must connect directly to the neutral lug on the breaker, and the breaker's pigtail must connect to the panel neutral bus.
The THQL2115GFT is the newer version of this breaker that includes an automatic self-test feature to ensure the ground fault circuitry is functioning properly. The THQL2115GF is the standard version without the automatic self-test function.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.