ABB / General ElectricTHQL2130GFT
Quantity
New
Quantity
ABB / General ElectricTHQL2130GFT
ABB / General ElectricTHQL2120GF1
ABB / General ElectricTHQL2120GFT
ABB / General ElectricTHQL2140GF1
| Brand | ABB / General Electric |
|---|---|
| Series | THQL |
| Amperage | 25A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE PowerMark Gold Load Centers, GE A-Series Panelboards, ABB ReliaHome Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment, Auxiliary Switch |
| Accessories | Pigtail Neutral |
| Standards | HACR, NEMA AB 1, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Self-Test |
This breaker is designed for use in GE PowerMark Gold load centers, GE A-Series panelboards, and ABB ReliaHome load centers. It requires two standard 1-inch spaces for plug-on installation.
The THQL2125GFT is the direct replacement for the discontinued THQL2125GF. The T suffix indicates the addition of an automatic self-test feature, which periodically verifies the ground-fault circuitry to comply with updated UL 943 standards.
The THQL2125GFT is a Class A Ground Fault Circuit Interrupter (GFCI) designed to trip when it detects a ground fault of 5mA. It provides personnel protection for specialized 25A circuits.
This breaker features a pigtail neutral. The coiled white pigtail wire must be connected directly to the panel neutral bus bar, while the load neutral wire connects to the designated neutral lug on the breaker itself.
Yes, 2-pole GFCI breakers like the THQL2125GFT can protect 120/240V multi-wire branch circuits (shared neutral circuits). The load neutral must be routed to the breaker so it can accurately monitor current imbalances across both ungrounded conductors and the neutral.
LIG stands for Long-Time, Instantaneous, and Ground-Fault. This means the thermal-magnetic trip unit provides standard overload (Long-Time) and short-circuit (Instantaneous) protection, alongside the integrated ground-fault sensing.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.