Engineered for heavy-duty industrial applications, the CFD63B200L delivers robust current-limiting protection. This 200A, 3-pole Sentron breaker utilizes a thermal-magnetic trip mechanism with long-time and instantaneous (LI) functions. Designed as a unit mount FD frame device, it fits into Siemens Sentron panelboards and enclosures. With a 200 kAIC rating at 480VAC, this MCCB handles high-fault environments using rapid blow-apart contacts and a reliable fuseless design.
Are line and load lugs included with the CFD63B200L?
Yes, the "L" suffix in the catalog number indicates that this breaker comes factory-equipped with line and load lugs. These lugs accept 6 AWG to 350 kcmil copper or 4 AWG to 350 kcmil aluminum wire.
How is the CFD63B200L installed in Siemens Sentron panels?
This is a unit mount, feed-thru circuit breaker. It bolts directly to the backpan or mounting plate of Siemens Sentron panelboards, switchboards, and enclosures, rather than plugging into a busbar system.
What does the adjustable magnetic trip on this breaker control?
The adjustable magnetic trip allows electricians to set the instantaneous short-circuit pickup level. This provides better coordination with other protective devices in the system while the thermal overload element remains fixed.
What does the "LI" trip function code mean on this breaker?
The "LI" designation indicates that the thermal-magnetic trip unit provides Long-Time (L) overload protection and Instantaneous (I) short-circuit protection.
Why does the CFD63B200L have different interrupting ratings at different voltages?
Interrupting capacity depends on the system voltage. This breaker can safely clear a 200kA fault at 480VAC, but its capacity decreases to 100kA at 600VAC and 50kA in 500VDC applications.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.