Skip to main content

Square D HGL36060U31X Molded Case Circuit Breaker

  • 60A
  • 3 Pole
  • Unit Mount
Square D HGL36060U31X
Molded Case Circuit Breaker
Brand Square D
SKU HGL36060U31X
Select Item Condition
Earn 1218 SuperPoints
  • 60A
  • 3 Pole
  • Unit Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.

Square D HGL36060U31X - 60A 3 Pole Molded Case Circuit Breaker

New

$1,218.00 Check Stock

Quantity

Similar Items

Description

Engineered for industrial applications, the Square D HGL36060U31X is a 3-pole, 60A electronic trip molded case circuit breaker. It delivers reliable power distribution for PowerPacT H-Frame enclosures, switchboards, and NF or NQ panelboards. This unit-mount MCCB offers a robust 65kA interrupting capacity at 240V. Equipped with a Micrologic 3.2 trip unit, it provides adjustable long-time and instantaneous (LI) protection with true RMS sensing for superior coordination.

Specifications

Key specifications
Brand Square D
Part Number HGL36060U31X
Series HGL
Amperage 60A
Poles 3
Mounting Style Unit Mount
Voltage 240VAC, 480VAC, 600VAC
Phase 3
AIC Rating 65kA @ 240VAC, 35kA @ 480VAC, 18kA @ 600VAC
Electrical ratings
Amperage Range 24-60A
Fit and installation
Frame Type HGL
Terminal Type Lugs
For Use With PowerPacT H-Frame Enclosures, Switchboards, Industrial Control Panels, NF Panelboards (Main), NQ Panelboards (Main)
Wire Gauge 14-3/0 AWG (Al/Cu)
Max Wire 3/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Adjustable
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle
Accessories Micrologic 3.2 Trip Unit (Factory Installed)
Standards CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval CE, CSA, IEC, NOM, UL
Temp Rating -25C to 70C
Construction Features Current Limiting, HACR Rated, Reverse Feed, True RMS Sensing, Visual Trip Indicator

Product FAQs

8 answers
What enclosures and panelboards are compatible with the HGL36060U31X circuit breaker?

This unit-mount H-frame breaker is compatible with PowerPacT H-Frame enclosures, industrial control panels, and switchboards. It can also be utilized as a main breaker in Square D NF and NQ panelboards.

What type of trip unit is included with the HGL36060U31X?

The U31X suffix indicates this breaker is equipped with a Micrologic 3.2 electronic trip unit. This solid-state trip unit provides adjustable Long-Time (L) and Instantaneous (I) protection settings for precise coordination.

What are the standard lugs provided on this H-frame breaker?

The HGL36060U31X comes standard with AL150HD mechanical lugs on both the line and load sides. These lugs accept 14 to 3/0 AWG aluminum or copper wire.

What does the G in the HGL36060U31X part number signify?

The G designates the interrupting capacity tier within the PowerPacT H-Frame series. It provides a short-circuit current rating of 65kA at 240VAC, 35kA at 480VAC, and 18kA at 600VAC.

Can I use the HGL36060U31X to replace an older thermal-magnetic H-frame breaker?

Yes, this breaker shares the same physical footprint and mounting dimensions as other unit-mount PowerPacT H-frame breakers. However, you must verify that the Micrologic 3.2 electronic trip unit and its LI protection profile meet your specific engineering requirements.

What is the recommended torque for the AL150HD lugs on this 60A breaker?

The standard AL150HD mechanical lugs require specific torque depending on the wire size used. For 14 to 10 AWG wire, the specified torque is 44.3 lb-in (5 N.m). Always verify the exact torque requirements printed on the breaker faceplate or lug before terminating larger conductors.

Does the HGL36060U31X provide ground fault protection?

No. The Micrologic 3.2 trip unit only provides Long-Time (L) and Instantaneous (I) protection. It does not include Ground Fault (G) or Short-Time (S) protection functions.

Can this 3-pole breaker be used in a single-phase application?

Yes, Square D PowerPacT H-frame breakers with standard Micrologic trip units are marked for single-phase use on 240VAC circuits. You can use any two poles for the connection.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.