Eaton / Cutler-HammerBAB3080HS
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3080H |
| Series | BAB |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3080H-R |
| Series | BAB |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3080HS
Eaton / Cutler-HammerBAB3090HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3080H |
| Series | BAB |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
This Quicklag breaker is designed for use in Eaton Pow-R-Line panelboards (including PRL1a, PRL2a, PRL3a, and PRL4a) configured for bolt-on branch breakers. It is also backward compatible with many legacy Cutler-Hammer and Westinghouse commercial panelboards.
It features an extended tang line terminal that bolts directly to the panelboard bus bar for a secure, high-vibration resistant connection. The load side utilizes standard box lugs for your field wiring.
Yes, Eaton BAB series breakers from 15A to 100A, including this 80-amp model, are fully HACR rated for use with commercial HVAC systems and motor loads.
Yes. Eaton acquired Cutler-Hammer and the distribution equipment lines from Westinghouse. The current Eaton BAB3080H is the exact, direct replacement for older Westinghouse and Cutler-Hammer breakers bearing the same catalog number.
The BAB3080H provides a 10 kAIC rating at 240VAC. If your electrical system requires a 22 kAIC rating, you must upgrade to the QBHW series equivalent (catalog number QBHW3080H), provided your panelboard is designed to accept it.
The load-side box lugs are rated to accept 8 AWG through 1/0 AWG copper or aluminum wire. Ensure you follow the specific strip length and torque values printed directly on the side of the breaker during installation.
No. A 3-pole circuit breaker like the BAB3080H is explicitly manufactured for 3-phase electrical systems to protect three ungrounded conductors. Single-phase applications require a 1-pole or 2-pole breaker.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.