Eaton / Cutler-HammerBAB3090HS
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3100HS |
| Series | BAB |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Shunt Trip |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3100HS-R |
| Series | BAB |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Shunt Trip |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3090HS
Eaton / Cutler-HammerBAB3080HS
Eaton / Cutler-HammerBAB3070HS
Eaton / Cutler-HammerBAB3060HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3100HS |
| Series | BAB |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Shunt Trip |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
It is a bolt-on breaker engineered for Eaton Pow-R-Line series panelboards and legacy Westinghouse panelboards designed for Quicklag frame breakers. It will not fit in standard plug-on residential load centers.
The 'HS' suffix designates that this breaker includes a factory-installed 120VAC shunt trip. This allows the breaker to be tripped remotely by an external voltage signal, a common requirement for emergency shutdown systems and building automation.
While some generic descriptions state a smaller range, the correct wire capacity for this 100A Quicklag breaker is #8 to 1/0 AWG for both copper and aluminum conductors. Always torque the lugs to the manufacturer specifications printed on the breaker label.
You can, but it is not recommended unless you need the 120VAC remote trip capability. The 'HS' variant includes extra coil wires for the shunt trip. If you simply need standard overcurrent protection, use the base BAB3100 catalog number.
Yes. Eaton acquired Cutler-Hammer and continues to manufacture the Quicklag line. A modern Eaton BAB breaker is an exact drop-in replacement for legacy Cutler-Hammer and Westinghouse BAB series breakers.
Yes. Like most of the Eaton Quicklag BAB family, this breaker is HACR rated, making it fully approved by the NEC for protecting heating, air conditioning, and refrigeration motor circuits.
When a 120V signal is applied to the shunt coil, the breaker handle will move to the center tripped position. To restore power, you must first remove the 120V control signal, manually push the handle fully to the Off position to reset the internal mechanism, and then switch it to On.
Yes. The 240VAC rating is a maximum voltage threshold. This three-pole breaker is perfectly suited for standard three-phase, four-wire 208Y/120V commercial applications.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.