Eaton / Cutler-HammerGHB3080S1
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3080 |
| Series | GHB |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line 2 (PRL2) Panelboards, Eaton Pow-R-Line 3 (PRL3) Panelboards, Series C Panelboards |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3080-R |
| Series | GHB |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line 2 (PRL2) Panelboards, Eaton Pow-R-Line 3 (PRL3) Panelboards, Series C Panelboards |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Eaton / Cutler-HammerGHB3080S1
Eaton / Cutler-HammerGHB3090S1
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | GHB3080 |
| Series | GHB |
| Amperage | 80A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line 2 (PRL2) Panelboards, Eaton Pow-R-Line 3 (PRL3) Panelboards, Series C Panelboards |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Alarm Switch, Auxiliary Switch, Shunt Trip, Undervoltage Release |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
It is designed to bolt into Eaton Pow-R-Line 2 (PRL2), Pow-R-Line 3 (PRL3), and Series C panelboards. It is not suitable for Pow-R-Line 1 (PRL1) enclosures.
No. The 480Y/277V rating indicates it is exclusively for solidly grounded Wye systems. It is not rated for use on three-phase 480V Delta ungrounded or corner-grounded systems.
Yes. Eaton acquired both the Cutler-Hammer and Westinghouse distribution lines. A new Eaton GHB3080 is an exact drop-in replacement for legacy breakers carrying the same catalog number.
Yes, all Eaton G-frame molded case circuit breakers, including the GHB series, are HACR rated for safely protecting heating, air conditioning, and refrigeration circuits.
Yes. Eaton G-frame circuit breakers do not have line and load directional restrictions, making them suitable for reverse feed applications if required by your panel layout.
As a standard G-frame breaker, it is 1 inch wide per pole. The 3-pole GHB3080 requires three 1-inch spaces, taking up 3 inches of total width on the panel bus.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.